AgCl-coated silver fabricated with the thermal-electrolytic method can be used to prepare more reproducible reference electrodes than Ag/AgCl prepared with alternative methods such as electrolytic and chemical AgCl deposition or thermal fabrication. However, thermal-electrolytic fabrication requires a scaffold material upon which to build the layers upon. Platinum and rhodium have been used for this purpose as they are mechanically strong and chemically inert, but their cost is prohibitive for wider application. Herein, we report the stability of Ag/AgCl reference electrodes built atop a titanium scaffold using the thermal-electrolytic method and the use of these Ti/Ag/AgCl constructs in capillary-based reference electrodes. Electrochemical characterization shows that the probable presence of small amounts of oxygen at the Ti/Ag interface does not affect the reference electrode performance; in particular, over a wide pH range, the half-cell potential is pH independent. The electrical resistance of the Ti/Ag/AgCl/KCl system is dominated by the charge transfer resistance at the interface of the AgCl to KCl solution but is kept very small by the large AgCl surface area and a high solution concentration of chloride. The resulting high exchange current minimizes the effect of system impurities on the reference half-cell potential. Capillary-based reference electrodes comprising Ti/Ag/AgCl show exceptionally low potential drifts (as low as 0.03 ± 2.01 μV/h) and standard deviations of the potential at or below ±0.5 mV over a 60 h period. These capillary-based reference electrodes are suitable for very small sample volumes while still providing a free-flowing liquid junction that prevents reference electrode contamination.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.3c05382 | DOI Listing |
Int J Surg
December 2024
Department of Neurosurgery, Stanford University, Stanford, Palo Alto, California, USA.
Deep brain stimulation (DBS) has emerged as a crucial therapeutic strategy for various neurological and psychiatric disorders. Precise target localization is essential for optimizing therapeutic outcomes, necessitating advanced neuroimaging techniques. Normative atlases provide standardized references for accurate electrode placement, enhancing treatment customization and efficacy.
View Article and Find Full Text PDFJ Affect Disord
January 2025
School of Medicine and Health, Department of Diagnostic and Interventional Neuroradiology, Technical University of Munich, Munich, Germany; School of Medicine and Health, TUM-NIC Neuroimaging Center, Technical University of Munich, Munich, Germany.
Aim: This study investigates the effects of transcranial direct current stimulation (tDCS) on brain network connectivity in individuals with obsessive-compulsive disorder (OCD).
Methods: In a randomized, double-blind, sham-controlled experimental design anodal tDCS (vs. sham) was applied in a total of 43 right-handed patients with OCD, targeting the right pre-supplementary motor area (pre-SMA).
J Electromyogr Kinesiol
January 2025
Hacettepe University, Faculty of Medicine, Department of Neurology, Ankara, Turkey.
Objectives: Jitter analysis with concentric needle electrode of the thoracic 9 (T9) paraspinal muscle (PM), where the needle EMG examination at rest is difficult, was performed in both amyotrophic lateral sclerosis (ALS) patients and the controls.
Methods: For the T9 PM, both upper limit for mean and individual mean consecutive difference (MCD) values and spike numbers were calculated according to jitter values of pairs from controls. In addition to the descriptive statistics, differences between two groups and T9 PM needle EMG and jitter analysis findings of patients were compared (p = 0.
Talanta
January 2025
College of Agricultural Engineering, Shanxi Agricultural University, Taigu, 030801, China; Dryland Farm Machinery Key Technology and Equipment Key Laboratory of Shanxi Province, Taigu, 030801, China.
This study introduces an innovative electrochemical biosensor, engineered through the functionalization screen-printed electrode (SPE) with a coordination complex comprised of 4-mercaptobenzoic acid (4-MBA) and copper ions (Cu), achieving precise quantitative determination of glyphosate. Electrodepositing gold nanoparticles (AuNPs) onto the electrode surface, forming a self-assembled monolayer (SAM) of 4-MBA via thiol-gold interactions, and immobilizing Cu via coordination bonding with the monolayer, finalizing the electrochemical biosensor construction as Cu/4-MBA/AuNPs/SPE. The successful modification of the biosensor interface is confirmed through scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and electrochemical characterization.
View Article and Find Full Text PDFTalanta
January 2025
Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093, Warsaw, Poland. Electronic address:
An idea of using ion-exchanger salt containing optically active cations to prepare ion-selective membranes is proposed. Although the presence of an ion-exchanger in the composition of neutral ionophore based sensors is necessary, the choice of available salts for cation-selective sensors preparation, is usually limited to sodium or potassium compounds. In this work we propose application of an alternative salt, using a cation optically active both in absorption and emission mode as a mobile one.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!