The current digital dentistry workflow has streamlined dental restoration production, but the effectiveness of digital virtual design and 3D printing for restorations still needs evaluation. This study explores the impact of model-free digital design and 3D-printing placement angles on restorations, including single crowns and long bridges produced with and without casts. The restorations are 3D printed using resin at placement angles of 0°, 60°, and 90°. Each group of samples was replicated ten times, resulting in a total of 120 restorations. The Root Mean Square Error (RMSE) value was used to evaluate the surface integrity of the restoration. In addition, the contact space, edge gap, and occlusal space of restorations produced by different processes were recorded. The results indicate that there was no significant difference in the RMSE value of the crown group ( > 0.05). Changing the bridge restoration angle from 0° to 90° resulted in RMSE values increasing by 2.02 times (without casts) and 2.39 times (with casts). Furthermore, the marginal gaps in the crown group were all less than 60 μm, indicating good adaptation. In contrast, the bridge group showed a significant increase in marginal gaps at higher placement angles ( > 0.05). Based on the findings, virtual fabrication without casts does not compromise the accuracy of dental restorations. When the position of the long bridge exceeds 60 degrees, the error will increase. Therefore, designs without casts and parallel placement result in higher accuracy for dental restorations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10814425 | PMC |
http://dx.doi.org/10.3390/dj12010002 | DOI Listing |
Regen Biomater
November 2024
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Prince of Songkla University, Hatyai 90110, Thailand.
Alveolar ridge loss presents difficulties for implant placement and stability. To address this, alveolar ridge preservation (ARP) is required to maintain bone and avoid the need for ridge augmentation using socket grafting. In this study, a scaffold for ARP was created by fabricating a 3D porous dense microfiber silk fibroin (mSF) embedded in poly(vinyl alcohol) (PVA), which mimics the osteoid template.
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Department of Orthopaedic Surgery, Murup Hospital, Changwon, South Korea.
Introduction: Medial open wedge-high tibial osteotomy (MOW-HTO) is a standard procedure for treating moderate varus arthritis in active adults. The reason for its popularity is having lesser complications than other types of HTO. However, it is not devoid of challenges.
View Article and Find Full Text PDFBMC Oral Health
January 2025
4th Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, No. 22, Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China.
Background: The stability of soft and hard tissues surrounding the implant is not only a matter of aesthetics, but also affects the long-term stability of the implant. The present study was to explore the influence of buccal mucosa width/height (W/H) ratio, emergence profile and buccal bone width on peri-implant soft and hard tissue changes in the posterior region.
Methods: Fifty-eight posterior implant restoration cases were recruited in this study.
J Clin Med
January 2025
Interventional Radiology Department, Adana Dr. Turgut Noyan Application and Research Center, Başkent University, 01250 Adana, Turkey.
: The objective of the current research is to assess the benefits that come with antegrade ureteral stenting coupled with imaging techniques in children and also provide a new classification based on the ureter's morphological elements. : Between 2011 and 2024, 107 antegrade stent placement procedures performed in 71 pediatric patients aged 0-12 years who could not undergo retrograde double-J stent placement were retrospectively analyzed. According to the morphologic structure of the ureter, four categories were classified as normal, straight/slightly angled, S-shaped, and spiral-shaped.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok 10400, Thailand.
Injuries involving the Atlas (C1) and Axis (C2) vertebrae of the cervical spine present significant clinical challenges due to their complex anatomy and potential for severe neurological impairment. Traditional imaging methods often lack the detailed visualization required for precise surgical planning. This study aimed to develop high-resolution 3D models of the C1 and C2 vertebrae to perform a comprehensive morphometric analysis, identify gender differences, and assess bilateral symmetry to enhance surgical accuracy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!