We evaluated the diagnostic performance of the STANDARD i-Q COVID-19 Ag Test, which was developed to detect viral antigens, using nasal and oral swabs. Sixty positive and 100 negative samples were analyzed. We determined the distribution of the Ct values according to the day of sample collection after symptom onset, the diagnostic performance of the total samples and subgroups separated by Ct value or time of sample collection, and the Ct value at which maximal accuracy was expected. No differences were observed in Ct values, except for the samples obtained on the day of symptom onset. The diagnostic sensitivity and specificity of the oral swabs were 75.0 and 100.0%, respectively, whereas those of the nasal swabs were 85.0 and 98.0%, respectively. The sensitivity was higher in samples with a high viral load collected earlier than those collected later, although the difference was not significant. False-negative results were confirmed in all samples with a Ct value ≥ 30.0. These results indicate that tests using oral and nasal swabs are helpful for diagnosing acute symptomatic cases with suspected high viral loads. Our tests exhibited relatively low sensitivity but high specificity rates, indicating the need to assess negative antigen test results.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10814936 | PMC |
http://dx.doi.org/10.3390/diagnostics14020231 | DOI Listing |
Afr J Paediatr Surg
September 2024
Department of Anaesthesia, Faculty of Medical Sciences, Khaja Bandanawaz University, Kalburgi, Karnataka, India.
Aim: The aim of this study is to report our experience in the treatment of congenital buried penis using a simplified technique of retrograde progression of inner preputial skin for reconstruction and overcome skin shortage.
Methods: This is a retrospective multi-institutional study conducted in the Department of Pediatric Surgery, I Q City Medical College and Hospital, Durgapur, West Bengal, India, and the Department of Paediatric Surgery, Rajiv Gandhi Super Specialty Hospital/Raichur Institute of Medical Sciences, Raichur, Karnataka, India, over a period of 3 years (from March 2019 to February 2022). A total of 14 cases of primary congenital buried penis were operated in the specified period.
The independent optical dual-single-sideband (dual-SSB) signal generation and detection can be achieved by an optical in-phase/quadrature (I/Q) modulator and one single photodiode (PD). The dual-SSB signal is able to carry two different information. After PD detection, the optical dual-SSB signal can be converted into an electrical millimeter-wave (mm-wave) signal.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2024
Department of Laboratory Medicine, Konkuk University Medical Center, Seoul 05030, Republic of Korea.
We evaluated the diagnostic performance of the STANDARD i-Q COVID-19 Ag Test, which was developed to detect viral antigens, using nasal and oral swabs. Sixty positive and 100 negative samples were analyzed. We determined the distribution of the Ct values according to the day of sample collection after symptom onset, the diagnostic performance of the total samples and subgroups separated by Ct value or time of sample collection, and the Ct value at which maximal accuracy was expected.
View Article and Find Full Text PDFVaccines (Basel)
September 2023
CSL Seqirus, Waltham, MA 02451, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!