Rational design of a FA1-targeting anti-interference fluorescent probe for the point-of-care testing of albuminuria.

Int J Biol Macromol

College of Material Science and Engineering, Shenzhen University, 518060 Shenzhen, China. Electronic address:

Published: March 2024

Albuminuria is a crucial urine biomarker of human unhealthy events such as kidney diseases, cardiovascular diseases, and diabetes. However, the accurate diagnosis of albuminuria poses a significant challenge owing to the severe interference from urine fluorescence and urine drugs. Here, we report a novel flavone-based fluorescent probe, DMC, by incorporating the FA1-targeting methylquinazoline group into a flavone skeleton with the extend π-conjugation. DMC exhibited a rapid response time, high sensitivity, and selectivity towards human serum albumin (HSA) in urine. Moreover, the red-shifted fluorescence and the FA1-targeted HSA-binding of DMC efficiently mitigated the interference from both urine fluorescence and urine drug metabolites. Furthermore, the establishment of a portable testing system highlighted the potential for point-of-care testing, offering a user-friendly and accurate approach to diagnose A2-level and A3-level albuminuria. We expect that the success of this DMC-based diagnostic platform in real urine samples can signify a significant advancement in early clinical diagnosis of albuminuria and its associated diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijbiomac.2024.129723DOI Listing

Publication Analysis

Top Keywords

fluorescent probe
8
point-of-care testing
8
diagnosis albuminuria
8
interference urine
8
urine fluorescence
8
fluorescence urine
8
urine
7
albuminuria
5
rational design
4
design fa1-targeting
4

Similar Publications

Heterogeneity in Fluorescence-Stained Sperm Membrane Patterns and Their Dynamic Changes Towards Fertilization in Mice.

Front Biosci (Landmark Ed)

January 2025

Graduate School of Life and Environmental Sciences, Integrated Graduate School of Medicine, Engineering, and Agricultural Sciences, University of Yamanashi, 400-8510 Kofu, Japan.

Background: Sperm represent a heterogeneous population crucial for male reproductive success. Additionally, sperm undergo dynamic changes during maturation and capacitation. Despite these well-established processes, the complex nature of sperm heterogeneity and membrane dynamics remains elusive.

View Article and Find Full Text PDF

Background: In neuroscience, Ca imaging is a prevalent technique used to infer neuronal electrical activity, often relying on optical signals recorded at low sampling rates (3 to 30 Hz) across multiple neurons simultaneously. This study investigated whether increasing the sampling rate preserves critical information that may be missed at slower acquisition speeds.

Methods: Primary neuronal cultures were prepared from the cortex of newborn pups.

View Article and Find Full Text PDF

Benzo[1,2-b:6,5-b']dithiophene-4,5-diamine: A New Fluorescent Probe for the High-Sensitivity and Real-Time Visual Monitoring of Phosgene.

Sensors (Basel)

January 2025

State Key Laboratory of Marine Resource Utilization in South China Sea, School of Chemistry and Chemical Engineering, Hainan University, Haikou 570228, China.

The detection of highly toxic chemicals such as phosgene is crucial for addressing the severe threats to human health and public safety posed by terrorist attacks and industrial mishaps. However, timely and precise monitoring of phosgene at a low cost remains a significant challenge. This work is the first to report a novel fluorescent system based on the Intramolecular Charge Transfer (ICT) effect, which can rapidly detect phosgene in both solution and gas phases with high sensitivity by integrating a benzo[1,2-b:6,5-b']dithiophene-4,5-diamine (BDTA) probe.

View Article and Find Full Text PDF

In a search for dyes photoactivatable with visible light, fluorenes with substituents at positions 2 and 7 were prepared, and their absorption and emission spectra were studied. In particular, the synthesis route to 9-diazofluorenes with 2-(N,N-dialkylamino) and N-modified 7-(4-pyridyl) substituents was established. These compounds are initially non-fluorescent, undergo photolysis with UV or blue light, and-in non-polar media-provide orange- to red-emitting products with a large separation between absorption and emission bands.

View Article and Find Full Text PDF

In recent years, the near-infrared (NIR) fluorescence theranostic system has garnered increasing attention for its advantages in the simultaneous diagnosis- and imaging-guided delivery of therapeutic drugs. However, challenges such as strong background fluorescence signals and rapid metabolism have hindered the achievement of sufficient contrast between tumors and surrounding tissues, limiting the system's applicability. This study aims to integrate the pegylation strategy with a tumor microenvironment-responsive approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!