Background: Intrapartum cardiotocographic monitoring of fetal heart rate by abdominal external ultrasound transducer without simultaneous maternal heart rate recording has been associated with increased risk of early neonatal death and other asphyxia-related neonatal outcomes. It is unclear, however, whether this increase in risk is independently associated with fetal surveillance method or is attributable to other factors.

Objective: This study aimed to compare different fetal surveillance methods and their association with adverse short- and long-term fetal and neonatal outcomes in a large retrospective cohort of spontaneous term deliveries.

Study Design: Fetal heart rate and maternal heart rate patterns were recorded by cardiotocography during labor in spontaneous term singleton cephalic vaginal deliveries in the Hospital District of Helsinki and Uusimaa, Finland between October 1, 2005, and September 30, 2023. According to the method of cardiotocography monitoring at birth, the cohort was divided into the following 3 groups: women with ultrasound transducer, women with both ultrasound transducer and maternal heart rate transducer, and women with internal fetal scalp electrode. Umbilical artery pH and base excess values, low 1- and 5-minute Apgar scores, need for intubation and resuscitation, neonatal intensive care unit admission for asphyxia, neonatal encephalopathy, and early neonatal death were used as outcome variables.

Results: Among the 213,798 deliveries that met the inclusion criteria, the monitoring type was external ultrasound transducer in 81,559 (38.1%), both external ultrasound transducer and maternal heart rate recording in 62,268 (29.1%), and fetal scalp electrode in 69,971 (32.7%) cases, respectively. The rates of both neonatal encephalopathy (odds ratio, 1.48; 95% confidence interval, 1.08-2.02) and severe acidemia (umbilical artery pH <7.00 and/or umbilical artery base excess ≤-12.0 mmol/L) (odds ratio, 2.03; 95% confidence interval, 1.65-2.50) were higher in fetuses of women with ultrasound transducer alone compared with those of women with concurrent external fetal and maternal heart rate recording. Monitoring with ultrasound transducer alone was also associated with increased risk of neonatal intubation for resuscitation (odds ratio, 1.22; 95% confidence interval, 1.03-1.44). A greater risk of severe neonatal acidemia was observed both in the ultrasound transducer (odds ratio, 2.78; 95% confidence interval, 2.23-3.48) and concurrent ultrasound transducer and maternal heart rate recording (odds ratio, 1.37; 95% confidence interval, 1.05-1.78) groups compared with those monitored with fetal scalp electrodes. No difference in risk of neonatal encephalopathy was found between newborns monitored with concurrent ultrasound transducer and maternal heart rate recording and those monitored with fetal scalp electrodes.

Conclusion: The use of external ultrasound transducer monitoring of fetal heart rate without simultaneous maternal heart rate recording is associated with higher rates of neonatal encephalopathy and severe neonatal acidemia. We suggest that either external fetal heart rate monitoring with concurrent maternal heart rate recording or internal fetal scalp electrode be used routinely as a fetal surveillance tool in term deliveries.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajog.2024.01.011DOI Listing

Publication Analysis

Top Keywords

heart rate
28
maternal heart
20
ultrasound transducer
20
external ultrasound
12
simultaneous maternal
8
neonatal
8
fetal heart
8
rate recording
8
early neonatal
8
neonatal death
8

Similar Publications

Circadian Misalignment Impacts Cardiac Autonomic Modulation in Adolescence.

Sleep

January 2025

Sleep Research & Treatment Center, Department of Psychiatry & Behavioral Health, Penn State University, College of Medicine, Hershey PA, USA.

Study Objectives: Although heart rate variability (HRV), a marker of cardiac autonomic modulation (CAM), is known to predict cardiovascular morbidity, the circadian timing of sleep (CTS) is also involved in autonomic modulation. We examined whether circadian misalignment is associated with blunted HRV in adolescents as a function of entrainment to school or on-breaks.

Methods: We evaluated 360 subjects from the Penn State Child Cohort (median 16y) who had at least 3-night at-home actigraphy (ACT), in-lab 9-h polysomnography (PSG) and 24-h Holter-monitoring heart rate variability (HRV) data.

View Article and Find Full Text PDF

Prediction of pre-eclampsia using maternal hemodynamic parameters at 12 + 0 to 15 + 6 weeks.

Ultrasound Obstet Gynecol

January 2025

Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, SAR, China.

Objectives: To compare the maternal hemodynamic profile at 12 + 0 to 15 + 6 weeks' gestation in women who subsequently developed pre-eclampsia (PE) and those who did not, and to assess the screening performance of maternal hemodynamic parameters for PE in combination with the Fetal Medicine Foundation (FMF) triple test, including maternal factors (MF), mean arterial pressure (MAP), uterine artery pulsatility index and placental growth factor.

Methods: This was a prospective case-control study involving Chinese women with a singleton pregnancy who underwent preterm PE screening at 11 + 0 to 13 + 6 weeks' gestation using the FMF triple test, between February 2020 and February 2023. Women identified as being at high risk (≥ 1:100) for preterm PE by the FMF triple test were matched 1:1 with women identified as low risk (< 1:100) for maternal age ± 3 years, maternal weight ± 5 kg and date of screening ± 14 days.

View Article and Find Full Text PDF

Heart failure is a complex clinical syndrome and pediatric heart failure (PHF) has a high mortality rate. Early diagnosis is crucial for treatment and management of PHF. In clinical practice, various tests and examinations play a key role in the diagnosis of PHF, including continuously updated biomarkers, echocardiography, and cardiac magnetic resonance imaging.

View Article and Find Full Text PDF

Background: Despite the physiological advantages of positive end-expiratory pressure (PEEP), its optimal utilization during one-lung ventilation (OLV) remains uncertain. We aimed to investigate whether individualized PEEP titration by lung compliance is associated with a reduced risk of postoperative pulmonary complications during OLV.

Methods: We searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials until April 1, 2024, to identify published randomized controlled trials that compared individualized PEEP titration by lung compliance with fixed PEEP during OLV.

View Article and Find Full Text PDF

Catheter-directed therapy for pulmonary embolism in pediatrics: a systematic review and meta-analysis.

Thromb J

January 2025

Pediatric Emergency Department, St. Christopher's Hopsoital for Children, Philadelphia, PA, USA.

Background: Acute pulmonary embolism (PE) is a serious and potentially fatal condition that is relatively rare in the pediatric population. In patients presenting with massive/submassive PE, catheter-directed Therapy (CDT) presents an emerging therapeutic modality by which PE can be managed.

Methods: Electronic databases were systematically searched through May 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!