B vitamins are essential for human life and their disorders can cause a variety of diseases. Solid-phase extraction (SPE) coupled to LC-MS/MS is a preferred technique for determining multiple B vitamins, however, their complexity in real biological matrices makes it hard to achieve satisfactory recovery and accuracy when simultaneous detection. In this study, a novel automated multi-cycle magnetic SPE (MSPE) coupled to the LC-MS/MS method was established using a mixed-mode anion exchange magnetic adsorbent for the simultaneous extraction of six functional B vitamins, including methylmalonic acid, riboflavin, pantothenic acid, 4-pyridoxic acid, folic acid, and 5-methyltetrahydrofolate. After three consecutive MSPE cycles, the recoveries of all analytes were between 51.5% and 89.6%. The method exhibited excellent sensitivity and linearity, with a dynamic range of 200-fold (R > 0.99 for all analytes), exceptional accuracy (ranging between 95.4% and 105.6%) and precision (with RSDs ≤ 6.2%) without significant matrix effects or interferences. Compared to manual SPE method, the automated multi-cycle MSPE method has better feasibility and greater vitamin coverage. It shows a high correlation with the manual method for the detection of 5-methyltetrahydrofolate and folate (R > 0.99). A study of patients from the gastroenterology department showed that those undergoing surgery and those with malignancies may be at risk of folate deficiency. In addition, patients with hyperhomocystinemia had higher levels of methylmalonic acid and lower levels of 5-methyltetrahydrofolate, which correlated with homocysteine levels (R = 0.404 and -0.311, respectively) and showed dose-response relationships. This method is highly automated and cost-effective, with minimal systematic error, making it suitable for the analysis of clinical samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2024.115989 | DOI Listing |
PLoS One
September 2024
Faculty of Medicine, Cardiology Department, Universiti Teknologi MARA (UiTM), Shah Alam, Malaysia.
Background: Regional Wall Motion Abnormality (RWMA) serves as an early indicator of myocardial infarction (MI), the global leader in mortality. Accurate and early detection of RWMA is vital for the successful treatment of MI. Current automated echocardiography analyses typically concentrate on peak values from left ventricular (LV) displacement curves, based on LV contour annotations or key frames during the heart's systolic or diastolic phases within a single echocardiographic cycle.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
June 2024
CONNECT-AI Research Center, Yonsei University College of Medicine, Seoul, South Korea.
To enhance M-mode echocardiography's utility for measuring cardiac structures, we developed and evaluated an artificial intelligence (AI)-based automated analysis system for M-mode images through the aorta and left atrium [M-mode (Ao-LA)], and through the left ventricle [M-mode (LV)]. Our system, integrating two deep neural networks (DNN) for view classification and image segmentation, alongside an auto-measurement algorithm, was developed using 5,958 M-mode images [3,258 M-mode (LA-Ao), and 2,700 M-mode (LV)] drawn from a nationwide echocardiographic dataset collated from five tertiary hospitals. The performance of view classification and segmentation DNNs were evaluated on 594 M-mode images, while automatic measurement accuracy was tested on separate internal test set with 100 M-mode images as well as external test set with 280 images (140 sinus rhythm and 140 atrial fibrillation).
View Article and Find Full Text PDFJ Pharm Biomed Anal
April 2024
Central Laboratory, Shanghai Xuhui Central Hospital/Zhongshan-Xuhui Hospital, Fudan University, Shanghai 200031, PR China; Shanghai Engineering Research Center of Phase I Clinical Research & Quality Consistency Evaluation for Drugs, Shanghai 200031, PR China; Institute of Clinical Mass Spectrometry, Shanghai Academy of Experimental Medicine, Shanghai 200031, PR China. Electronic address:
B vitamins are essential for human life and their disorders can cause a variety of diseases. Solid-phase extraction (SPE) coupled to LC-MS/MS is a preferred technique for determining multiple B vitamins, however, their complexity in real biological matrices makes it hard to achieve satisfactory recovery and accuracy when simultaneous detection. In this study, a novel automated multi-cycle magnetic SPE (MSPE) coupled to the LC-MS/MS method was established using a mixed-mode anion exchange magnetic adsorbent for the simultaneous extraction of six functional B vitamins, including methylmalonic acid, riboflavin, pantothenic acid, 4-pyridoxic acid, folic acid, and 5-methyltetrahydrofolate.
View Article and Find Full Text PDFBreast Cancer Res
August 2017
Massachusetts General Hospital Cancer Center, Richard B. Simches Research Building, 185 Cambridge Street, Boston, MA, 02114, USA.
Background: Absence of pathologic complete response (pCR) to neoadjuvant chemotherapy (NACT) correlates with poor long-term survival in patients with triple negative breast cancer (TNBC). These incomplete treatment responses are likely determined by mechanisms that enable cancer cells to resist being killed. However, the detailed characterization of a drug-resistant cancer cell state in residual TNBC tissue after NACT has remained elusive.
View Article and Find Full Text PDFAnal Chem
August 2012
Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec, Canada H3A 0B8.
In this technical note, a liquid-liquid extraction technique was performed using pneumatic liquid recirculation on a centrifugal microfluidic device. Non-contact pneumatic pumping enabled a multi-cycle liquid-liquid extraction process using aqueous iodine in a potassium iodide solution and hexadecane while requiring a minimal amount of space on the device. The extraction process was completely automated on the device following sample introduction and required only 50 s for each extraction cycle.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!