Setup and characterisation according to NEMA NU 4 of thePET scanner, a PET system dedicated for plant sciences.

Phys Med Biol

IBG-2: Plant Sciences, Forschungszentrum Jülich GmbH, Wilhelm-Johnen-Str., D-52425 Jülich, Germany.

Published: February 2024

ThePET system is a plant dedicated positron emission tomography (PET) scanner consisting of fully digital photo multipliers with lutetium-yttrium oxyorthosilicate crystals and located inside a custom climate chamber. Here, we present the setup ofPET, its data processing and image reconstruction together with its performance.The performance characterization follows the national electrical manufacturers association (NEMA) standard for small animal PET systems with a number of adoptions due to the vertical oriented bore of a PET for plant sciences. In addition temperature stability and spatial resolution with a hot rod phantom are addressed.The spatial resolution for aNa point source at a radial distance of 5 mm to the center of the field-of-view (FOV) is 1.45 mm, 0.82 mm and 1.88 mm with filtered back projection in radial, tangential and axial direction, respectively. A hot rod phantom withF gives a spatial resolution of up to 1.6 mm. The peak noise-equivalent count rates are 550 kcps @ 35.08 MBq, 308 kcps @ 33 MBq and 45 kcps @ 40.60 MBq for the mouse, rat and monkey size scatter phantoms, respectively. The scatter fractions for these phantoms are 12.63%, 22.64% and 55.90%. We observe a peak sensitivity of up to 3.6% and a total sensitivity of up to= 2.17%. For the NEMA image quality phantom we observe a uniformity of %= 4.22% with ordinary Poisson maximum likelihood expectation-maximization with 52 iterations. Here, recovery coefficients of 0.12, 0.64, 0.89, 0.93 and 0.91 for 1 mm, 2 mm, 3 mm, 4 mm and 5 mm rods are obtained and spill-over ratios of 0.08 and 0.14 for the water-filled and air-filled inserts, respectively.ThePET and its laboratory are now in routine operation for the administration of [C]COand non-invasive measurement of transport and allocation ofC-labelled photoassimilates in plants.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad22a2DOI Listing

Publication Analysis

Top Keywords

spatial resolution
12
plant sciences
8
hot rod
8
rod phantom
8
setup characterisation
4
characterisation nema
4
nema thepet
4
thepet scanner
4
pet
4
scanner pet
4

Similar Publications

To image or not to image: Use of imaging mass spectrometry in biomedical lipidomics.

Prog Lipid Res

January 2025

Lipids in Human Pathology, Institut d'Investigació Sanitària Illes Balears (IdISBa) - Health Research Institute of the Balearic Islands, Ctra. Valldemossa 79, Module G, Floor -1, E-07120 Palma, Balearic Islands, Spain; Research Unit, University Hospital Son Espases, Ctra Valldemossa 79, E-07120 Palma, Balearic Islands, Spain. Electronic address:

Lipid imaging mass spectrometry (LIMS) allows for establishing the bidimensional distribution of lipid species within a tissue section. One of the main advantages is the generation of spatial information on lipid species distribution at a spatial (lateral) resolution bordering on single-cell resolution with no need to isolate cells. Thus, LIMS images demonstrate, with a level of detail never described before, that lipid profiles are highly sensitive to cell type and pathophysiological state.

View Article and Find Full Text PDF

A novel super-resolution STED microscopy analysis approach to observe spatial MCU and MICU1 distribution dynamics in cells.

Biochim Biophys Acta Mol Cell Res

January 2025

Molecular Biology and Biochemistry, Gottfried Schatz Research Center, Medical University of Graz, Neue Stiftingtalstraße 6/4 EAST, 8010 Graz, Austria; BioTechMed, Graz, Austria. Electronic address:

The uptake of Ca by mitochondria is an important and tightly controlled process in various tissues. Even small changes in the key proteins involved in this process can lead to significant cellular dysfunction and, ultimately, cell death. In this study, we used stimulated emission depletion (STED) microscopy and developed an unbiased approach to monitor the sub-mitochondrial distribution and dynamics of the mitochondrial calcium uniporter (MCU) and mitochondrial calcium uptake 1 (MICU1) under resting and stimulated conditions.

View Article and Find Full Text PDF

Purpose: To develop an educational, interactive, ultra-high resolution, in vivo magnetic resonance (MR) neurography atlas for direct visualization of the brachial plexus and upper extremity.

Methods: A total of 16 adult volunteers without known peripheral neuropathy underwent magnetic resonance (MR) neurography of the brachial plexus and upper extremity. To improve vascular suppression, subjects received an intravenous infusion of ferumoxytol.

View Article and Find Full Text PDF

Diazotrophs have made significant contributions to marine nitrogen cycles. However, their distribution patterns and determined mechanisms have not been fully understood, particularly at the small regional scales. Here, the diazotrophic community structure by different sample sizes (0.

View Article and Find Full Text PDF

In Sri Lanka, climate change and recurrent droughts pose significant threats to agricultural communities. Village water storage tanks have been used in countries in South Asia since the third millennium BC. According to the National Tanks Survey, Sri Lanka has some 23,000 small tanks of 80 ha or less; however, 21 percent are currently non-functional due to decades of neglect.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!