The widely deployed ways to capture a set of unorganized points, e.g., merged laser scans, fusion of depth images, and structure-from- x , usually yield a 3-D noisy point cloud. Accurate normal estimation for the noisy point cloud makes a crucial contribution to the success of various applications. However, the existing normal estimation wisdoms strive to meet a conflicting goal of simultaneously performing normal filtering and preserving surface features, which inevitably leads to inaccurate estimation results. We propose a normal estimation neural network (Norest-Net), which regards normal filtering and feature preservation as two separate tasks, so that each one is specialized rather than traded off. For full noise removal, we present a normal filtering network (NF-Net) branch by learning from the noisy height map descriptor (HMD) of each point to the ground-truth (GT) point normal; for surface feature recovery, we construct a normal refinement network (NR-Net) branch by learning from the bilaterally defiltered point normal descriptor (B-DPND) to the GT point normal. Moreover, NR-Net is detachable to be incorporated into the existing normal estimation methods to boost their performances. Norest-Net shows clear improvements over the state of the arts in both feature preservation and noise robustness on synthetic and real-world captured point clouds.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNNLS.2024.3352974DOI Listing

Publication Analysis

Top Keywords

normal estimation
20
noisy point
12
normal filtering
12
point normal
12
normal
11
norest-net normal
8
estimation neural
8
neural network
8
3-d noisy
8
point
8

Similar Publications

The current research introduces a model-free ultra-local model (MFULM) controller that utilizes the multi-agent on-policy reinforcement learning (MAOPRL) technique for remotely regulating blood pressure through precise drug dosing in a closed-loop system. Within the closed-loop system, there exists a MFULM controller, an observer, and an intelligent MAOPRL algorithm. Initially, a flexible MFULM controller is created to make adjustments to blood pressure and medication dosages.

View Article and Find Full Text PDF

The increasing availability of coarse-scale climate simulations and the need for ready-to-use high-resolution variables drive the climate community to the challenge of reducing computational resources and time for downscaling purposes. To this end, statistical downscaling is gaining interest as a potential strategy for integrating high-resolution climate information obtained through dynamical downscaling over limited years, providing a clear understanding of the gains and losses in combining dynamical and statistical downscaling. In this regard, several questions can be raised: (i) what is the performance of statistical downscaling, assuming dynamical downscaling as a reference over a shared time window; (ii) how much the performance of statistical downscaling is affected by changes in the number of years available for training; (iii) how does the climate normal considered for the training affect the predictions.

View Article and Find Full Text PDF

Evaluation of renal functional reserve with oral protein load or new ultrasound test.

J Nephrol

January 2025

Department of Medicine, Surgery and Neurosciences, Nephrology, Dialysis and Transplantation Unit, University Hospital of Siena, Siena, Italy.

Background: Renal functional reserve (RFR) measures the difference between the stimulated glomerular filtration rate (GFR) and the baseline GFR to detect early signs of renal functional decline. The protein load test (RFR-T) is the gold standard for RFR assessment but is a complicated procedure. Renal intraparenchymal resistance index (RRI) variation test (DRRI-T) is a non-invasive method to measure renal function reserve using ultrasound.

View Article and Find Full Text PDF

Accurate and continuous blood glucose monitoring is essential for effective diabetes management, yet traditional finger pricking methods are often inconvenient and painful. To address this issue, photoplethysmography (PPG) presents a promising non-invasive alternative for estimating blood glucose levels. In this study, we propose an innovative 1-second signal segmentation method and evaluate the performance of three advanced deep learning models using a novel dataset to estimate blood glucose levels from PPG signals.

View Article and Find Full Text PDF

The role of non-invasive stress testing in the diagnosis of coronary microvascular disease.

Cardiovasc Revasc Med

December 2024

Department of Cardiology, Tel Aviv Sourasky Medical Center, affiliated with the School of Medicine, Tel Aviv University, Israel.

Background: Angina with non-obstructive coronary artery disease (ANOCA) is commonly observed in patients with stable angina undergoing coronary angiography. Current guidelines recommend non-invasive stress testing as the first step in diagnosing coronary microvascular disease (CMD). This study aims to evaluate the diagnostic value of non-invasive stress testing in patients invasively diagnosed with CMD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!