Impaired fracture healing, specifically non-union, has been found to occur up to 14% in tibial shaft fractures. The current standard of care to treat non-union often requires additional surgeries which can result in long recovery times. Injectable-based therapies to accelerate fracture healing have the potential to mitigate the need for additional surgeries. Gene therapies have recently undergone significant advancements due to developments in nanotechnology, which improve mRNA stability while reducing immunogenicity. In this study, we tested the efficacy of mineral coated microparticles (MCM) and fluoride-doped MCM (FMCM) to effectively deliver firefly luciferase (FLuc) mRNA lipoplexes (LPX) to the fracture site. Here, adult mice underwent a tibia fracture and stabilization method and all treatments were locally injected into the fracture. Level of osteogenesis and amount of bone formation were assessed using gene expression and histomorphometry respectively. Localized and systemic inflammation were measured through gene expression, histopathology scoring and measuring C-reactive protein (CRP) in the serum. Lastly, daily IVIS images were taken to track and measure transfection over time. MCM-LPX-FLuc and FMCM-LPX-FLuc were not found to cause any cytotoxic effects when tested . When measuring the osteogenic potential of each mineral composition, FMCM-LPX-FLuc trended higher in osteogenic markers through qRT-PCR than the other groups tested in a murine fracture and stabilization model. Despite FMCM-LPX-FLuc showing slightly elevated and levels in the fracture callus, inflammation scoring of the fracture callus did not result in any differences. Additionally, an acute systemic inflammatory response was not observed in any of the samples tested. The concentration of MCM-LPX-FLuc and FMCM-LPX-FLuc that was used in the murine fracture model did not stimulate bone when analyzed through stereological principles. Transfection efficacy and kinetics of delivery platforms revealed that FMCM-LPX-FLuc prolongs the luciferase signal both and . These data together reveal that FMCM-LPX-FLuc could serve as a promising mRNA delivery platform for fracture healing applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10803474PMC
http://dx.doi.org/10.3389/fbioe.2023.1295313DOI Listing

Publication Analysis

Top Keywords

fracture healing
16
fracture
11
mineral coated
8
coated microparticles
8
additional surgeries
8
fracture stabilization
8
gene expression
8
mcm-lpx-fluc fmcm-lpx-fluc
8
murine fracture
8
fracture callus
8

Similar Publications

Introduction: Patellar fractures are rare at 1% incidence of all fractures. However, they can cause significant functional impairments due to the patella's role in knee joint extension. Current scoring systems lack objectivity in assessing patellar healing.

View Article and Find Full Text PDF

[Cancellous bone harvesting from the distal radius for reconstruction of bone defects in the hand].

Oper Orthop Traumatol

December 2024

Unfall‑, Hand- und Ellenbogenchirurgie, Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum zu Köln, Köln, Deutschland.

Objective: Extraction of cancellous bone from the distal radius for reconstructive procedures on the hand.

Indications: All reconstructive procedures on the hand for which a corticocancellous and/or vascularized bone graft or a large amount of cancellous bone is not required.

Contraindications: Acute distal radius fracture, osteosynthesis material embedded in the distal radius, e.

View Article and Find Full Text PDF

Near-Infrared Spectroscopy Allows for Monitoring of Bone Fracture Healing via Changes in Oxygenation.

J Funct Biomater

December 2024

Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, 66421 Homburg, Germany.

Bone fractures are associated with hypoxia, but no longitudinal studies of perfusion measurements in human patients have been reported despite the clinical and research potential. In this longitudinal observational cohort study, the near-infrared spectroscopy (NIRS) device PortaMon was used to assess oxy-(OHb), deoxy-(HHb) and total (tHb) haemoglobin, as well as the differences between OHb and HHb (Hb) and the tissue saturation index (TSI) at three different depths in the fracture gap. Linear mixed effect models were fitted to analyse time effects.

View Article and Find Full Text PDF

Background: Achieving bony union in scaphoid nonunion fractures is challenging. Various bone grafts have been studied using headless compression screws (HCS) fixation. However, the impact of bone graft choice on bone healing with volar locking plates (VLP) use is less clear.

View Article and Find Full Text PDF

Objective: Type IV fragility fractures of pelvis (FFP IV) are serious and complicated and the treatment is challengeable. Robotic-assisted minimally invasive triangular fixation (RoboTFX) is a new and advanced technique to treat this injury. The objective of this report is to evaluate the clinical outcomes of FFP IV treated with RoboTFX.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?