Compression Dressing versus Noncompressive Transparent Eye Shield after Ptosis Surgery.

Plast Reconstr Surg Glob Open

From the Department of Ophthalmology, Ludwig-Maximilians-University Munich, Munich, Germany.

Published: January 2024

Background: We aimed to investigate the effect of compression dressing on edema, ecchymosis, pain, and ocular surface irritation after ptosis surgery.

Methods: After ptosis correction [anterior levator reinsertion (and resection) (ALR), if necessary additional blepharoplasty], the eye was randomized for compression dressing or transparent eye shield. Edema and ecchymosis were scored on a four-point rating scale by a blinded observer 1 day (D1), 1 week (D7), and 8 weeks (D56) after surgery; the same was done for scar formation regarding redness and bulging at D7 and D56. Aesthetic outcome was ranked by patient and blinded observer using the Global Aesthetic Improvement Score at D1, D7, and D56. Postoperative pain was scored using a visual analogue scale (0 to 10) at D1. Impairment after surgery by dressing or eye shield was evaluated at D1.

Results: Ecchymosis, edema, scar formation, and aesthetic outcome ranked by the patient and blinded observer did not differ between the groups with compression dressing and eye shield at any day of follow-up ( > 0.05). Postoperative pain and impairment were the same in both groups ( > 0.05). One case of corneal erosion occurred in the group with compression dressing at D1 ( = 0.342). At D7, corneal staining was increased in the group without compression dressing ( = 0.930).

Conclusions: Compression dressing after ALR does not reduce ecchymosis, edema, or postoperative pain and has no effect on early scar formation or aesthetic results. To prevent corneal erosion caused by the dressing, it can be omitted after ALR without inferiority for the early postoperative results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10805438PMC
http://dx.doi.org/10.1097/GOX.0000000000005548DOI Listing

Publication Analysis

Top Keywords

compression dressing
28
eye shield
16
blinded observer
12
scar formation
12
postoperative pain
12
transparent eye
8
dressing
8
edema ecchymosis
8
aesthetic outcome
8
outcome ranked
8

Similar Publications

This work demonstrates the preparation of fast-swelling hydrogels based on poly(vinyl alcohol) (PVA) and tamarind xyloglucan (XG), utilizing freeze-drying to achieve an interconnected macroporous structure. Although XG is non-toxic and abundant, it has poor mechanical properties. Therefore, XG was mixed with PVA and crosslinked with citric acid (CA).

View Article and Find Full Text PDF

Medical device-related pressure injuries (MDRPIs) pose a significant risk in the home health environment, where patients may lack continuous professional oversight. Devices commonly used in the home environment with the potential to cause a MDRPI include but are not limited to nasogastric tubes, feeding tubes, nasal cannulas, nasal cannula prongs, airway pressure masks, indwelling urinary catheters, sequential compression devices, dressings, bandages, and tracheostomies. When a medical device is used for an extended period, it can lead to unrelieved pressure or edema, cause friction and/or shearing that impairs sensation, reduces circulation, and alters the microclimate.

View Article and Find Full Text PDF

Emergency bleeding presents significant challenges such as high blood flow and rapid hemorrhaging. However, many existing hemostatic bandages face limitations, including the uncontrolled release of hemostatic agents, insufficient mechanical strength, poor adhesion, and complex manufacturing processes. To address these limitations, we developed a multifunctional hydrogel bandage for emergency hemostasis using a one-pot synthesis method.

View Article and Find Full Text PDF

Background: For patients with head and neck cancer who have undergone microvascular free flap surgery, securing a tracheostomy collar onto the neck using the traditional method (ie, with tracheostomy ties) is contraindicated because the ties may compress the newly vascularized tissue. However, no clear guidance exists for the use of other methods in these patients. Current techniques often use safety pins, which can cause injury to staff members.

View Article and Find Full Text PDF

Bacterial cellulose (BC) is a novel biocompatible polymeric biomaterial with a wide range of biomedical uses, like tissue engineering (TE) scaffolds, wound dressings, and drug delivery. Although BC lacks good cell adhesion due to limited functionality, its tunable surface chemistry still holds promise. Here, hydroxyapatite (HA) was incorporated into a citrate-modified BC (MBC) using the biomimetic synthesis in simulated body fluid (SBF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!