The integrity of the foveal insertion of the triangular fibrocartilage complex (TFCC) is currently assessed by inference using the hook test. Using dry arthroscopic techniques, the primary author observed that many patients with painful distal radioulnar joint (DRUJ) instability and a positive hook test had an intact foveal insertion. This study was performed to determine whether a positive hook test is a reliable index of a tear of the foveal insertion. The hook test is performed using a probe to elevate the TFCC off the ulna head toward the articular surface of the lunate. In this study, the hook test was considered positive if the TFCC could be elevated to bridge more than 80% of the space between the TFCC and the articular surface of the lunate. A retrospective study was performed using the medical records and arthroscopic videos of 113 patients who had clinical signs of DRUJ instability and underwent arthroscopic surgery performed by the primary author in 2020. It was documented whether the hook test was positive or negative, whether the foveal insertion was intact, abnormal or absent, and whether there were peripheral (dorsal or volar) tears of the TFCC. Sensitivity and specificity were calculated using arthroscopic findings as the reference standard. The sensitivity of the hook test was found to be 100%, and the specificity was 7.0%. The positive predictive value for foveal pathology was found to be 12.3% and the negative predictive value 100%. The diagnostic accuracy of the hook test in determining the presence of foveal tears was found to be 17.7%. The diagnostic accuracy of the hook test in determining the presence of a TFCC abnormality was 99.1%. A positive hook test is indicative of a tear of the TFCC, but it is not anatomically specific for a tear of the foveal insertion. To reliably assess the foveal insertion, it must be visualized and probed using dry arthroscopic techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10803151 | PMC |
http://dx.doi.org/10.1055/s-0043-1770077 | DOI Listing |
Arch Orthop Trauma Surg
January 2025
The Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 123, Ta Pei Road, Niao Sung Dist, Kaohsiung, Taiwan.
Introduction: The optimal management strategy for unstable distal clavicular fractures remains controversial. Recent studies on plate techniques have reported good-to-excellent outcomes with no serious complications. The questions are that: (1) Does the use of wire augmentation with locking plate in distal part (distal wire augmentation) reduce radiographic loss of reduction (RLOR) and get earlier bony union in distal clavicular fractures? (2) Which fixation methods are associated with a higher incidence of acromioclavicular (AC) joints arthritis or subluxation? We collected and analyzed clinical studies on different plate fixation methods for unstable fractures to identify the best surgical modality.
View Article and Find Full Text PDFBiol Lett
January 2025
Department of Forestry and Natural Resources, Purdue University, Forestry Building, 195 Marsteller Street, West Lafayette, IN 47907, USA.
Temperate fishes often spawn in response to environmental cues, such as temperature, thereby facilitating larval emergence concurrent with suitable biotic and abiotic conditions, such as plankton blooms. Climatic changes may alter the reproductive phenology of spring- and autumn-spawning freshwater fish populations. Such effects may depend on the sensitivity of reproductive phenology to ambient temperatures.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Key Laboratory of New Technology for Construction of Cities in Mountain Area, School of Civil Engineering, Chongqing University, Chongqing 400000, China.
According to the mechanical characteristics of joints in steel-concrete composite bridge decks under the combined bending and shear, improved joint details with simple structure and convenient construction were studied, including lapped U-bars, lapped headed bars, and lapped hook bars. In order to test the mechanical properties of the three joint details and compare them with the existing lapped/welded linear bars, the tests of five specimens were carried out. The cracking load, ultimate load, failure mode, crack pattern, and reinforcement strain were analyzed.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Stomatology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China.
Background: Proper torque control is crucial to the outcome of orthodontic treatment. This study aimed to employ finite element analysis to compare the torque capabilities of a novel spherical self-ligating bracket with a lock-hook system against those of commonly used passive self-ligating and conventional bracket systems, as well as to reveal the biomechanical changes in the periodontal ligament (PDL) during torque expression.
Methods: A maxillary right central incisor, along with its PDL and alveolar bone, were modeled.
Nat Commun
January 2025
Department of Materials, University of Oxford, Parks Road, Oxford, UK.
The Selective Metallization Technique shows promise for roll-to-roll in-line patterning of flexible electronics using evaporated metals, but challenges arise when applied to sputtering functional materials. This study overcomes these challenges with simultaneous sputtering of Bi-Sb-Te and evaporation of metal (Ag or Cu) for thermoelectric layers when using Selective Metallization Technique. Large-scale manufacturing is demonstrated through roll-to-roll processing of a 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!