Laser-induced fluorescence (LIF) Doppler spectroscopy using an optical vortex beam with an asymmetric intensity distribution, referred to as aOVLIF, is proposed as a new method to measure plasma flow velocity. LIF spectra were calculated numerically using typical laboratory low-temperature plasma parameters, and it was revealed that an ion flow across the beam produces a frequency shift of the spectra. This method also has the capability of temperature measurements. The propagation effects of asymmetric optical vortex beams are discussed assuming an actual experiment, and it is found that the sensitivity to the transverse flow velocity is approximately unchanged. The aOVLIF method, which exploits the inhomogeneous phase structure of optical vortices, can be applied to the determination of three-dimensional velocity vectors and promises to enhance the usefulness of conventional LIF spectroscopy using plane waves.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11229526PMC
http://dx.doi.org/10.1038/s41598-024-52179-0DOI Listing

Publication Analysis

Top Keywords

flow velocity
12
optical vortex
12
laser-induced fluorescence
8
asymmetric optical
8
vortex beams
8
three-dimensional flow
4
velocity
4
velocity determination
4
determination laser-induced
4
method
4

Similar Publications

The main advantages of microneedles are precise drug delivery through human skin, minimal tissue damage and painlessness. We conducted structural analysis and skin puncture studies of hollow microneedles using ANSYS for three materials: Hafnium Dioxide (HfO), Polyglycolic acid (PGA) and Polylactic acid (PLA). Firstly, we selected three lengths, three tip diameters and three base diameters to conduct a L(3) orthogonal experiment.

View Article and Find Full Text PDF

Dual-Modality Flow Phantom for Ultrasound and Optical Flow Measurements.

Phys Med Biol

January 2025

Schlegel Research Institute for Aging, University of Waterloo, 250 Laurelwood Drive, Waterloo, Ontario, N2L 3G1, CANADA.

As ultrasound-compatible flow phantoms are devised for performance testing and calibration, there is a practical need to obtain independent flow measurements for validation using a gold-standard technique such as particle image velocimetry (PIV). In this paper, we present the design of a new dual-modality flow phantom that allows ultrasound and PIV measurements to be simultaneously performed. Our phantom's tissue mimicking material is based on a novel hydrogel formula that uses propylene glycol to lower the freezing temperature of an ultrasound-compatible poly(vinyl) alcohol cryogel and, in turn, maintain the solution's optical transparency after thermocycling.

View Article and Find Full Text PDF

Current study presents an advanced method for improving the visualization of subsurface blood vessels using laser speckle contrast imaging (LSCI), enhanced through principal component analysis (PCA) filtering. By combining LSCI and laser speckle entropy imaging with PCA filtering, the method effectively separates static and dynamic components of the speckle signal, significantly improving the accuracy of blood flow assessments, even in the presence of static scattering layers located above and below the vessel. Experiments conducted on optical phantoms, with the vessel depths ranging from 0.

View Article and Find Full Text PDF

Measurement of blood flow during exercise is crucial for understanding physiological responses and performance outcomes. However, traditional methods are often invasive, costly, or require substantial training, limiting widespread research in this area. This study introduces the innovative use of limb-affixed ultrasound probe holders for vascular imaging during exercise to overcome these challenges.

View Article and Find Full Text PDF

Pulmonary artery (PA) flow analysis is crucial for understanding the progression of pulmonary hypertension (PH). We hypothesized that PA flow characteristics vary according to PH etiology. In this study, we used 4D flow cardiovascular magnetic resonance imaging (CMR) to compare PA flow velocity and wall shear stress (WSS) between patients with pulmonary arterial hypertension (PAH) and those with heart failure with preserved ejection fraction and pulmonary hypertension (PH-HFpEF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!