Wireless, miniaturised and distributed neural interfaces are emerging neurotechnologies. Although extensive research efforts contribute to their technological advancement, the need for real-time systems enabling simultaneous wireless information and power transfer toward distributed neural implants remains crucial. Here we present a complete wearable system including a software for real-time image capturing, processing and digital data transfer; an hardware for high radiofrequency generation and modulation via amplitude shift keying; and a 3-coil inductive link adapt to operate with multiple miniaturised receivers. The system operates in real-time with a maximum frame rate of 20 Hz, reconstructing each frame with a matrix of 32 × 32 pixels. The device generates a carrier frequency of 433.92 MHz. It transmits the highest power of 32 dBm with a data rate of 6 Mbps and a variable modulation index as low as 8 %, thus potentially enabling wireless communication with 1024 miniaturised and distributed intracortical microstimulators. The system is primarily conceived as an external wearable device for distributed cortical visual prosthesis covering a visual field of 20 . At the same time, it is modular and versatile, being suitable for multiple applications requiring simultaneous wireless information and power transfer to large-scale neural interfaces.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TBCAS.2024.3357626 | DOI Listing |
Biomed Phys Eng Express
January 2025
Department of Neurology and Neurological Sciences, Stanford Medicine, 213 Quarry Road, Palo Alto, California, 94305-5101, UNITED STATES.
Clinical adoption of innovative EEG technology is contingent on the non-inferiority of the new devices relative to conventional ones. We present the four key results from testing the signal quality of Zeto's WR19 EEG system against a conventional EEG system conducted on patients in a clinical setting. Methods: We performed 30-minute simultaneous recordings using the Zeto WR19 (zEEG) and a conventional clinical EEG system (cEEG) in a cohort of 15 patients.
View Article and Find Full Text PDFSci Rep
December 2024
Shaanxi Key Laboratory of Complex System Control and Intelligent Informantion Processing, Xi'an University of Technology, Xi'an 710048, China.
In the integrated radar and communication system (IRCS), the design of signal that can simultaneously satisfy the radar detection and communication transmission is very important and difficult. Recently, some new properties of a class of solvable chaotic system have been studied for wireless applications, such as low bit error rate (BER) wireless communications and low cost target detection. In this paper, a novel IRCS based on the chaotic signal is proposed, and the performance of proposed scheme is analyzed.
View Article and Find Full Text PDFAdv Mater
December 2024
Advanced Microscopy and Instrumentation Research Center, Harbin Institute of Technology, Harbin, 150080, P. R. China.
Nowadays, metasurfaces have attracted considerable attention due to their promising and advanced control of electromagnetic (EM) waves. However, it is still challenging to shape guided waves into desired free-space mode, while simultaneously manipulating spatial incident waves using a single metasurface. Herein, a class of metasurfaces capable of multiplexing guided and space waves is proposed to achieve advanced EM functionalities in microwave regions, which can find great application potentials in radar systems, wireless communications, and wireless power transfer (WPT).
View Article and Find Full Text PDFSensors (Basel)
November 2024
Optics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.
A respiration rate (RR) monitoring system was created by integrating a Fibre Bragg Grating (FBG) optical fibre sensor into a respirator mask. The system exploits the sensitivity of an FBG to temperature to identify an individual's RR by measuring airflow temperature variation near the nostrils and mouth. To monitor the FBG response, a portable, battery-powered, wireless miniature interrogator system was developed to replace a relatively bulky benchtop interrogator used in previous studies.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
Key Laboratory of Urban Rail Transit Intelligent Operation and Maintenance Technology & Equipment of Zhejiang Province, College of Engineering, Zhejiang Normal University, Jinhua, 321004, P. R. China.
Dielectric elastomers (DEs) have promising capabilities for soft electromechanical systems, including those for actuation and energy generation. However, their widespread application is restricted by electromechanical instability (EMI) and the requirement for high-voltage operation. This study presents a dual-modal DE system that effectively overcomes these limitations by leveraging a dual-membrane structure.