Purpose: The primary objective was to investigate if subjects with dry eyes had increased variability of keratometry measurements prior to cataract surgery compared to subjects with non-dry eyes. Secondary objectives were to determine which separate signs affected keratometry.

Patients And Methods: This study was part of a prospective interventional randomized controlled trial. After dry eye diagnostics were performed (signs only) subjects were divided into sign of dry eye (SDE) positive and negative groups. To investigate variability, we performed two keratometry measurements for each subject with three different optical biometers: Anterion (OCT optical biometer), Eyestar (combined OCT and reflection-based optical biometer), and Lenstar (reflection based-optical biometer).

Results: One hundred and thirty-one subjects were available for analysis. The variability of astigmatism was significantly higher for subjects with hyperosmolarity compared to normal eyes for the Lenstar, as was the percentage of eyes with variability of astigmatism greater than 0.25 D. The percentage of eyes with variability of average K greater than 0.25 D was higher for subjects with non-invasive keratograph break-up time <10 seconds (NIKBUT positive) compared to normal eyes for the Lenstar.

Conclusion: Combined diagnostic criteria (signs only) showed no statistically significant differences for keratometry measurements between SDE positive and negative. Eyes with hyperosmolarity and NIKBUT positive showed statistically higher variability of keratometry measurements compared to normal eyes for Lenstar, but not for the Anterion or Eyestar biometers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10800283PMC
http://dx.doi.org/10.2147/OPTH.S448168DOI Listing

Publication Analysis

Top Keywords

dry eye
12
keratometry measurements
12
cataract surgery
8
optical biometer
8
variability astigmatism
8
higher subjects
8
percentage eyes
8
eyes variability
8
greater 025
8
subjects
6

Similar Publications

Significance: Artificial tears remain the cornerstone for managing dry eye disease. The current study's real-world efficacy test of carboxymethylcellulose (CMC), polyethylene glycol (PEG) 400, or sodium hyaluronate (SH)-based lubricants highlights their similar effects on noninvasive tear film parameters over the short term. However, patients reported better relief with SH-based lubricants.

View Article and Find Full Text PDF

Dry eye disease (DED) has become increasingly prevalent in the digital era, largely due to prolonged screen exposure. The excessive use of digital devices contributes to inappropriate blink frequency and dynamics, leading to ocular surface dryness and discomfort. Additionally, digital screen use has broader implications for systemic health, including visual strain, headaches, and disrupted circadian rhythms caused by blue light exposure.

View Article and Find Full Text PDF

Purpose: This study aimed to determine the effect of intense pulsed light (IPL) treatment on meibomian gland disease.

Settings And Design: This is a prospective interventional study.

Methods: Seventy eyes of patients with dry eye disease undergoing three sessions of IPL therapy, 15 days apart, were included.

View Article and Find Full Text PDF

Developing hybrid fluorescence (FL)/room-temperature phosphorescent (RTP) materials in dry-state, aqueous, and organic solvents holds paramount importance in broadening their applications. However, it is extremely challenging due to dissolved oxygen and solvent-assisted relaxation causing RTP quenching in an aqueous environment and great dependence on SiO-based materials. Herein, an efficient endogenetic carbon dot (CD) strategy within melamine-formaldehyde (MF) microspheres to activate RTP of CDs has been proposed through the pyrolysis of isophthalic acid (IPA) molecules and branched-chain intra-microspheres.

View Article and Find Full Text PDF

Characterization and Role of Glucagon-Like Peptide 1 Receptor in the Lacrimal Gland: Novel Insights into Diabetic Dry Eye Pathogenesis.

Am J Pathol

December 2024

Department of Ophthalmology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, 510080, China. Electronic address:

This study aimed to investigate the expression of glucagon-like peptide 1 receptor (GLP-1R) in the lacrimal gland and explore the effects of topical application of GLP-1R agonist (GLP-1RA) on lacrimal gland function in a murine model of type 1 diabetes. Tear secretion was evaluated using phenol red threads, RNA sequencing (RNA-seq) was used to explore gene expression profiles associated with hyperglycemia-induced lacrimal gland injuries, and histological analysis was conducted to evaluate the degree of damage. The expression of GLP-1R in the lacrimal gland was first identified and a downregulation trend associated with diabetes was observed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!