The human body is a source of multiple types of energy, such as mechanical, thermal and biochemical, which can be scavenged through appropriate technological means. Mechanical vibrations originating from contraction and expansion of the radial artery represent a reliable source of displacement to be picked up and exploited by a harvester. The continuous monitoring of physiological biomarkers is an essential part of the timely and accurate diagnosis of a disease with subsequent medical treatment, and wearable biosensors are increasingly utilized for biomedical data acquisition of important biomarkers. However, they rely on batteries and their replacement introduces a discontinuity in measured signals, which could be critical for the patients and also causes discomfort. In the present work, the research into a novel 3D-printed wearable energy harvesting platform for scavenging energy from arterial pulsations via a piezoelectric material is described. An elastic thermoplastic polyurethane (TPU) film, which forms an air chamber between the skin and the piezoelectric disc electrode, was introduced to provide better adsorption to the skin, prevent damage to the piezoelectric disc and electrically isolate components in the platform from the human body. Computational fluid dynamics in the framework of COMSOL Multiphysics 6.1 software was employed to perform a series of coupled time-varying simulations of the interaction among a number of associated physical phenomena. The mathematical model of the harvester was investigated computationally, and quantification of the output energy and power parameters was used for comparisons. A prototype wearable platform enclosure was designed and manufactured using fused filament fabrication (FFF). The influence of the piezoelectric disc material and its diameter on the electrical output were studied and various geometrical parameters of the enclosure and the TPU film were optimized based on theoretical and empirical data. Physiological data, such as interdependency between the harvester skin fit and voltage output, were obtained.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10820656PMC
http://dx.doi.org/10.3390/mi15010118DOI Listing

Publication Analysis

Top Keywords

piezoelectric disc
12
energy harvesting
8
wearable biosensors
8
human body
8
tpu film
8
energy
5
3d-printed piezoelectric
4
piezoelectric microdevice
4
microdevice human
4
human energy
4

Similar Publications

Dental ultrasonic scalers are commonly employed in periodontal treatment; however, their ability to roughen tooth surfaces is a worry since roughness may increase plaque production, a key cause of periodontal disease. This research studied the influence of a piezoelectric ultrasonic scaler on the roughness of two distinct flowable composite filling materials. To do this, 10 disc-shaped samples were generated from each of the two flowable composite materials.

View Article and Find Full Text PDF

Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.

Materials And Methods: Two implant sites were prepared in the tibia of four minipigs.

View Article and Find Full Text PDF

Purpose: This pilot study evaluated and compared histomorphometric and immunohistochemical characteristics of peri-implant bone tissue after implant site preparation using piezoelectric tips versus conventional drills.

Material And Methods: Six patients with bilateral partial edentulism underwent a splitmouth protocol. Twelve alveolar ridges were randomized into six control implant sites prepared using conventional drills (Drill Group); and six test implant sites prepared using piezoelectric implant inserts (Piezo Group).

View Article and Find Full Text PDF

Piezoelectric materials directly convert between electrical and mechanical energies. They are used as transducers in applications such as nano-positioning and ultrasound imaging. Improving the properties of these devices requires piezoelectric materials capable of delivering a large longitudinal strain on the application of an electric field.

View Article and Find Full Text PDF

Ultrasound is an excellent way to acquire data that reveal useful information about systems operating in harsh environments, which may include elevated temperature, ionizing radiation, and aggressive chemicals. The effects of harsh environments on piezoelectric materials have been studied in much more depth than the other aspects of ultrasonic transducers used in pulse-echo mode. Therefore, finite element simulations and laboratory experiments are used to demonstrate the unique characteristics of pulse-echo immersion testing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!