Inertial measurement units (IMUs) need sensor-to-segment calibration to measure human kinematics. Multiple methods exist, but, when assessing populations with locomotor function pathologies, multiple limitations arise, including holding postures (limited by joint pain and stiffness), performing specific tasks (limited by lack of selectivity) or hypothesis on limb alignment (limited by bone deformity and joint stiffness). We propose a sensor-to-bone calibration based on bi-plane X-rays and a specifically designed fusion box to measure IMU orientation with respect to underlying bones. Eight patients undergoing total hip arthroplasty with bi-plane X-rays in their clinical pathway participated in the study. Patients underwent bi-plane X-rays with fusion box and skin markers followed by a gait analysis with IMUs and a marker-based method. The validity of the pelvis, thigh and hip kinematics measured with a conventional sensor-to-segment calibration and with the sensor-to-bone calibration were compared. Results showed (1) the feasibility of the fusion of bi-plane X-rays and IMUs in measuring the orientation of anatomical axes, and (2) higher validity of the sensor-to-bone calibration for the pelvic tilt and similar validity for other degrees of freedom. The main strength of this novel calibration is to remove conventional hypotheses on joint and segment orientations that are frequently violated in pathological populations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10819897 | PMC |
http://dx.doi.org/10.3390/s24020419 | DOI Listing |
Comput Biol Med
December 2024
Research Campus STIMULATE, University of Magdeburg, 39104, Germany; University Hospital Schleswig-Holstein Campus Kiel, Kiel, 24118, Germany.
Interventional neuroradiologists carry out their minimally-invasive procedure by using X-rays within the setup of a Bi-plane Digital Subtraction Angiography. This work provides an immersive virtual reality (VR) environment where the physicians can perform an simulated catheter-based intervention. Since radiation is invisible, the risk of radiation exposure can be enhanced virtually.
View Article and Find Full Text PDFSensors (Basel)
January 2024
Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, 1205 Geneva, Switzerland.
Inertial measurement units (IMUs) need sensor-to-segment calibration to measure human kinematics. Multiple methods exist, but, when assessing populations with locomotor function pathologies, multiple limitations arise, including holding postures (limited by joint pain and stiffness), performing specific tasks (limited by lack of selectivity) or hypothesis on limb alignment (limited by bone deformity and joint stiffness). We propose a sensor-to-bone calibration based on bi-plane X-rays and a specifically designed fusion box to measure IMU orientation with respect to underlying bones.
View Article and Find Full Text PDFJ Endourol
February 2024
Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
To evaluate the efficacy of supine percutaneous renal access by robot-assisted (RA) fluoroscopy and ultrasound (US) guidance in terms of procedural outcomes and surgeon workload. We conducted a multicenter, randomized, controlled benchtop study involving 32 urologists using a renal phantom model. RA puncture was performed using the developed version of automated needle targeting with X-ray (ANT-X), which determines the direction of the needle.
View Article and Find Full Text PDFAm J Cardiol
January 2024
Division of Cardiology, Department of Internal Medicine and Cardiovascular Center, National Taiwan University Hospital, Taipei, Taiwan; Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan. Electronic address:
Successful collateral channel (CC) crossing is an essential step in retrograde chronic total occlusion (CTO) percutaneous coronary interventions (PCIs). We previously developed a dedicated CC score based on CC size and tortuosity to facilitate target CC selection. Validation and comparison to other scoring systems were lacking.
View Article and Find Full Text PDFJ Biomech
September 2023
Department of Biomedical Engineering, University of Melbourne, Parkville, Victoria, Australia. Electronic address:
The ligamentous structures of the wrist stabilise and constrain the interactions of the carpal bones during active wrist motion; however, the three-dimensional translations and rotations of the scaphoid, lunate and capitate in the normal and ligament deficient wrist during planar and oblique wrist motions remain poorly understood. This study employed a computer-controlled simulator to replicate physiological wrist motion by dynamic muscle force application, while carpal kinematics were simultaneously measured using bi-plane x-ray fluoroscopy. The aim was to quantify carpal kinematics in the native wrist and after sequential sectioning of the scapholunate interosseous ligament (SLIL) and secondary scapholunate ligament structures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!