A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of True Bonding Strength for Adhesive Bonded Carbon Fiber-Reinforced Plastics. | LitMetric

Evaluation of True Bonding Strength for Adhesive Bonded Carbon Fiber-Reinforced Plastics.

Materials (Basel)

Department of Materials Science and Technology, Tokyo University of Science, Tokyo 125-8585, Japan.

Published: January 2024

Carbon fiber-reinforced thermoplastics (CFRTPs) have attracted attention in aerospace because of their superior specific strength and stiffness. It can be assembled by adhesive bonding; however, the existing evaluation of bonding strength is inadequate. For example, in a single-lap shear test, the weld zone fails in a combined stress state because of the bending moment. Therefore, the strength obtained experimentally is only the apparent strength. The true bonding strength was obtained via numerical analysis by outputting the local stress state at the initiation point of failure. In this study, the apparent and true bonding strengths were compared with respect to three types of strength evaluation tests to comprehensively evaluate bonding strength. Consequently, the single-lap shear test underestimates the apparent bonding strength by less than 14% of the true bonding strength. This indicates that care should be taken when determining the adhesion properties for use in numerical analyses based on experimental results. We also discussed the thickness dependence of the adhesive on the stress state and found that the developed shear test by compression reduced the discrepancy between apparent and true strength compared with the single-lap shear test and reduced the thickness dependence compared with the flatwise tensile test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10817254PMC
http://dx.doi.org/10.3390/ma17020394DOI Listing

Publication Analysis

Top Keywords

bonding strength
24
true bonding
16
shear test
16
single-lap shear
12
stress state
12
strength
11
bonding
8
carbon fiber-reinforced
8
apparent true
8
thickness dependence
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!