Background: The AAPM TG-43U1 formalism remains the clinical standard for dosimetry of low- and high-energy -emitting brachytherapy sources. TG-43U1 and related reports provide consensus datasets of TG-43 parameters derived from various published measured data and Monte Carlo simulations. These data are used to perform standardized and fast dose calculations for brachytherapy treatment planning.
Purpose: Monte Carlo TG-43 dosimetry parameters are commonly derived to characterize novel brachytherapy sources. RapidBrachyTG43 is a module of RapidBrachyMCTPS, a Monte Carlo-based treatment planning system, designed to automate this process, requiring minimal user input to prepare Geant4-based Monte Carlo simulations for a source. RapidBrachyTG43 may also perform a TG-43 dose to water-in-water calculation for a plan, substantially accelerating the same calculation performed using RapidBrachyMCTPS's Monte Carlo dose calculation engine.
Methods: TG-43 parameters , , , and were calculated using three commercial source models, one each of I, Ir, and Co, and were benchmarked to published data. TG-43 dose to water was calculated for a clinical breast brachytherapy plan and was compared to a Monte Carlo dose calculation with all patient tissues, air, and catheters set to water.
Results: TG-43 parameters for the three simulated sources agreed with benchmark datasets within tolerances specified by the High Energy Brachytherapy Dosimetry working group. A gamma index comparison between the TG-43 and Monte Carlo dose-to-water calculations with a dose difference and difference to agreement criterion of 1%/1 mm yielded a 98.9% pass rate, with all relevant dose volume histogram metrics for the plan agreeing within 1%. Performing a TG-43-based dose calculation provided an acceleration of dose-to-water calculation by a factor of 165.
Conclusions: Determination of TG-43 parameter data for novel brachytherapy sources may now be facilitated by RapidBrachyMCTPS. These parameter datasets and existing consensus or published datasets may also be used to determine the TG-43 dose for a plan in RapidBrachyMCTPS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mp.16948 | DOI Listing |
Front Pharmacol
January 2025
Department of Pharmacy, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing, Jiangsu, China.
Objectives: To assess the pharmacokinetics and pharmacodynamics of imipenem in a retrospective cohort of hospitalized Chinese older patients.
Methods: A population pharmacokinetic (PPK) model was constructed utilizing a nonlinear mixed-effects modeling approach. The final model underwent evaluation through bootstrap resampling and visual predictive checks.
Cureus
December 2024
Department of Radiology, Aichi Medical University, Nagakute, JPN.
Purpose In linac-based stereotactic radiosurgery (SRS) utilizing a multileaf collimator (MLC) for brain metastases (BMs), a volumetric-modulated arc (VMA) technique is indispensable for generating a suitable dose distribution with efficient planning and delivery. However, the optimal calculation grid spacing (GS) and statistical uncertainty (SU) of the Monte Carlo algorithm for VMA optimization have yet to be determined. This planning study aimed to examine the impacts of GS and GU settings on VMA-based SRS planning and to find the optimal combination for templating.
View Article and Find Full Text PDFBackground: Uncertainty about optimal tranexamic acid (TXA) dosage has led to significant practice variation in hip arthroplasty. We aimed to identify the optimal i.v.
View Article and Find Full Text PDFFertil Steril
January 2025
The Leonard Davis Institute of Health Economics, University of Pennsylvania, Philadelphia, PA; Department of Obstetrics and Gynecology, University of Pennsylvania, Philadelphia, PA.
Importance: Patients with uterine factor infertility (UFI) have few options for family building. Uterus transplant is a feasible treatment for some patients; however, cost remains a significant concern.
Objective: To compare the cost effectiveness of treatment for patients with absolute uterine factor infertility to achieve 1-2 singleton births by gestational carrier or uterus transplant DESIGN: Decision analysis from the United States healthcare sector perspective, with time horizons to achieve one or two singleton births.
Appl Radiat Isot
January 2025
Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan; Nuclear Science and Technology Development Center, National Tsing Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan. Electronic address:
In clinical boron neutron capture therapy (BNCT), the distribution of dose to a heterogeneous medium that is predicted by a treatment planning system (TPS) should be experimentally validated. A head phantom specifically developed for this purpose is described and demonstrated herein. The cylindrical phantom exhibits distinct regions made from four materials (polymethyl methacrylate, calcium phosphate, air, and boric acid) to approximate a head structure with explicitly defined skin, skull, and brain tissue with a cavity and tumor within.