Coded aperture snapshot spectral imaging (CASSI) is an important technique for capturing three-dimensional (3D) hyperspectral images (HSIs), and involves an inverse problem of reconstructing the 3D HSI from its corresponding coded 2D measurements. Existing model-based and learning-based methods either could not explore the implicit feature of different HSIs or require a large amount of paired data for training, resulting in low reconstruction accuracy or poor generalization performance as well as interpretability. To remedy these deficiencies, this paper proposes a novel HSI reconstruction method, which exploits the global spectral correlation from the HSI itself through a formulation of model-driven low-rank subspace representation and learns the deep prior by a data-driven self-supervised deep learning scheme. Specifically, we firstly develop a model-driven low-rank subspace representation to decompose the HSI as the product of an orthogonal basis and a spatial representation coefficient, then propose a data-driven deep guided spatial-attention network (called DGSAN) to adaptively reconstruct the implicit spatial feature of HSI by learning the deep coefficient prior (DCP), and finally embed these implicit priors into an iterative optimization framework through a self-supervised training way without requiring any training data. Thus, the proposed method shall enhance the reconstruction accuracy, generalization ability, and interpretability. Extensive experiments on several datasets and imaging systems validate the superiority of our method. The source code and data of this article will be made publicly available at https://github.com/ChenYong1993/LRSDN.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TIP.2024.3354127DOI Listing

Publication Analysis

Top Keywords

low-rank subspace
12
subspace representation
12
self-supervised deep
8
reconstruction accuracy
8
model-driven low-rank
8
deep
5
hsi
5
hyperspectral compressive
4
compressive snapshot
4
reconstruction
4

Similar Publications

Background: Photon-counting computed tomography (CT) is an advanced imaging technique that enables multi-energy imaging from a single scan. However, the limited photon count assigned to narrow energy bins leads to increased quantum noise in the reconstructed spectral images. To address this issue, leveraging the prior information in the spectral images is essential.

View Article and Find Full Text PDF

Aims: The aim of this study was to develop an ultra-short echo time 3D magnetic resonance imaging (MRI) method for imaging subacute myocardial infarction (MI) quantitatively and in an accelerated way. Here, we present novel 3D T- and T -weighted Multi-Band SWeep Imaging with Fourier Transform and Compressed Sensing (MB-SWIFT-CS) imaging of subacute MI in mice hearts .

Methods And Results: Relaxation time-weighted and under-sampled 3D MB-SWIFT-CS MRI were tested with manganese chloride (MnCl) phantom and mice MI model.

View Article and Find Full Text PDF

Extended homogeneous field correction method based on oblique projection in OPM-MEG.

Neuroimage

February 2025

Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, 310051, China; State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China; Hefei National Laboratory, Hefei, 230088, China. Electronic address:

Article Synopsis
  • OPM-MEG is a new non-invasive imaging technique that improves sensor flexibility but requires better noise suppression due to environmental factors.
  • Existing methods like homogeneous field correction (HFC) and spatiotemporal extended HFC (teHFC) have limitations in dealing with complex noise.
  • The proposed oblique projection method (opHFC) enhances noise suppression by accommodating non-orthogonal signal and noise subspaces, leading to improved signal quality in OPM-MEG applications.
View Article and Find Full Text PDF

Purpose: To implement a low-rank and subspace model-based reconstruction for 3D deuterium metabolic imaging (DMI) and compare its performance against Fourier transform-based (FFT) reconstruction in terms of spectral fitting reliability.

Methods: Both reconstruction methods were applied on simulated and experimental DMI data. Numerical simulations were performed to evaluate the effect of increasing acceleration factors.

View Article and Find Full Text PDF

Subspace learning using low-rank latent representation learning and perturbation theorem: Unsupervised gene selection.

Comput Biol Med

February 2025

Faculty of Engineering, Computing and the Environment, Kingston University, Penrhyn Road Campus, Kingston Upon Thames, London, KT1 2EE, UK.

In recent years, gene expression data analysis has gained growing significance in the fields of machine learning and computational biology. Typically, microarray gene datasets exhibit a scenario where the number of features exceeds the number of samples, resulting in an ill-posed and underdetermined equation system. The presence of redundant features in high-dimensional data leads to suboptimal performance and increased computational time for learning algorithms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!