A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fibrin Glue Acutely Blocks Distal Muscle Contraction after Confirmed Polyethylene Glycol Nerve Fusion: An Animal Study. | LitMetric

Background: Polyethylene glycol (PEG) is a synthetic, biodegradable, and hyperosmotic material promising in the treatment of acute peripheral nerve injuries. Our team set out to investigate the impact of fibrin glue upon PEG fusion in a rat model.

Methods: Eighteen rats underwent sciatic nerve transection and PEG fusion. Electrophysiologic testing was performed to measure nerve function and distal muscle twitch. Fibrin glue was applied and testing repeated. Due to preliminary findings, fibrin glue was applied to an uncut nerve in five rodents and testing was conducted before and after glue application. Mann-Whitney U tests were used to compare median values between outcome measures. A Shapiro-Wilk test was used to determine normality of data for each comparison, significance set at a value less than 0.05.

Results: PEG fusion was confirmed in 13 nerves with no significant change in amplitude ( = 0.054), latency ( = 0.114), or conduction velocity ( = 0.114). Stimulation of nerves following PEG fusion produced distal muscle contraction in 100% of nerves. Following application of fibrin glue, there was a significant reduction in latency ( = 0.023), amplitude ( < 0.001), and conduction velocity ( = 0.023). Stimulation of the nerve after application of fibrin glue did not produce distal muscle twitch. Five uncut nerves with fibrin glue application blocked distal muscle contraction following stimulation.

Conclusions: Our data suggest that fibrin glue alters the nerve's function. The immediate confirmation of PEG fusion via distal muscle twitch is blocked with application fibrin glue in this experimental model. Survival and functional outcome studies are necessary to understand if this has implications on the long-term functional outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10798741PMC
http://dx.doi.org/10.1097/GOX.0000000000005535DOI Listing

Publication Analysis

Top Keywords

fibrin glue
36
distal muscle
24
peg fusion
20
muscle contraction
12
muscle twitch
12
application fibrin
12
fibrin
9
glue
9
polyethylene glycol
8
glue applied
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!