This study examined whether the degree of abutment surface modification that may occur with regular periodontal instrumentation has a clinical impact in terms of increased plaque accumulation and increased peri-implant tissue inflammation on zirconia implant abutments. Thirteen patients who had zirconia implant crowns were recruited in this randomized clinical trial. Each patient acted as their control and had either the buccal or lingual surface of their screw-retained implant restoration scaled with a metallic scaler and the other surface with a non-metallic scaler at 3, 6, 9, and 12 months. Cytokine testing of the peri-implant crevicular fluid was completed at 0, 3, and 12 months for IL-2, IL-4, IL-6, IL-8, IL-10, TNF-α, or IFNγ. Implant crowns were removed at 12 months and evaluated under an atomic force microscope for the average roughness (Ra). The implant crowns were polished and re-inserted. The results were analyzed using the Kruskal-Wallis test, and post hoc tests were conducted with a significance level of α = 0.05. Significant differences in surface roughness (Ra) were observed between the metallic and non-metallic scalers. The median Ra values were 274.0 nm for metallic scalers and 147.1 nm for non-metallic scalers. However, there were no significant differences between the type of scaler used and the amount of clinical inflammation or cytokine production. Metallic scalers produced deeper, more aggressive surface alterations to the abutment/crown zirconia surface, but there was no statistically significant difference between the degree of surface alterations, amount of BOP, and the amplitude of cytokine inflammation produced.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10817302 | PMC |
http://dx.doi.org/10.3390/jfb15010009 | DOI Listing |
Contemp Clin Dent
December 2024
Department of Periodontology, Faculty of Dentistry, Mohamed V University, Rabat, Morocco.
Critical alveolar ridge defects can result from several causes. Ridge expansion is a technique that aims to increase the width of the bone crest. A male patient presented an edentulous segment which leads to be careful concerning the adjacent teeth.
View Article and Find Full Text PDFClin Oral Implants Res
January 2025
Department of Oral and Maxillofacial Radiology, School of Dentistry, Kashan University of Medical Sciences, Kashan, Iran.
Objective: This study evaluated ResNet-50 and U-Net models for detecting and segmenting vertical misfit in dental implant crowns using periapical radiographic images.
Methods: Periapical radiographs of dental implant crowns were classified by two experts based on the presence of vertical misfit (reference group). The misfit area was manually annotated in images exhibiting vertical misfit.
Front Toxicol
January 2025
Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy.
Solid lipid nanoparticles (SLNs) have gained interest as drug delivery carriers due to their efficient cellular internalization and increased therapeutic effect of the loaded drug, with minimal side effects. Although recently several studies have shown the possibility to administer SLNs during pregnancy to vehicle mRNA to the placenta, data about the effect of premating exposure to SLNs on pregnancy outcome are scant. Considering that assumption of drug-delivering nanocarriers in reproductive age may potentially affect women's reproductive health, the aim of the present study was to evaluate whether repeated oral administration of SLNs to female mice prior to mating would influence key pregnancy outcomes.
View Article and Find Full Text PDFCureus
January 2025
College of Dentistry, King Saud University, Riyadh, SAU.
In this case study, an all-ceramic (Emax) crown and a post and core restoration are used to successfully treat external inflammatory root resorption (EIRR) in a mandibular molar. A 21-year-old male patient was diagnosed with EIRR and hypercementosis after presenting with pain and significant damage to his lower right first molar. The patient chose a post and core restoration over extraction and implant placement due to budgetary constraints.
View Article and Find Full Text PDFBiomed Tech (Berl)
January 2025
Oral Technology, University of Bonn, Bonn, Germany.
Objectives: The aim of the present study was to investigate, whether polyetherketoneketone (PEKK) secondary crowns could be considered as alternative to gold standard in terms of their physical properties and manufacturing costs.
Methods: An upper jaw model with six implants was used. Frameworks with either 6 PEKK- or 6 electroplated secondary crowns were cemented in a wear simulator.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!