Hip implants have a modular structure which enables patient-specific adaptation but also revision of worn or damaged friction partners without compromising the implant-bone connection. To reduce complications during the extraction of ceramic inlays, this work presents a new approach of a shape-memory-alloy-actuator which enables the loosening of ceramic inlays from acetabular hip cups without ceramic chipping or damaging the metal cup. This technical in vitro study exam-ines two principles of heating currents and hot water for thermal activation of the shape-memory-alloy-actuator to generate a force between the metal cup and the ceramic inlay. Mechanical tests concerning push-in and push-out forces, deformation of the acetabular cup according to international test standards, and force generated by the actuator were generated to prove the feasibility of this new approach to ceramic inlay revision. The required disassembly force for a modular acetabular device achieved an average value of 602 N after static and 713 N after cyclic loading. The actuator can provide a push-out force up to 1951 N. In addition, it is shown that the necessary modifications to the implant modules for the implementation of the shape-memory-actuator-system do not result in any change in the mechanical properties compared to conventional systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10813518 | PMC |
http://dx.doi.org/10.3390/bioengineering11010075 | DOI Listing |
Bone Joint J
January 2025
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
Aims: The purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications.
Methods: We identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision.
Cureus
November 2024
Trauma and Orthopedic Surgery, Services Hospital Lahore, Lahore, PAK.
Objective To determine the outcomes of cemented modular bipolar hemiarthroplasty for displaced femoral neck fractures in the elderly. Methodology This prospective study involved 102 elderly patients with clinically and radiologically confirmed displaced femoral neck fractures and was conducted in the Department of Trauma and Orthopedic Surgery, Unit-1, Services Hospital, Lahore. Cemented bipolar hemiarthroplasty was performed on all patients.
View Article and Find Full Text PDFMed Biol Eng Comput
December 2024
Sch Mech Engn, Southwest Jiaotong Univ, Chengdu, 610031, People's Republic of China.
The demand for total hip replacement surgery is increasing year by year. However, the issue of hip prosthesis failure, particularly the modular acetabular cup, still exists. The performance and functional requirements of modular acetabular cups have not yet met clinical expectations.
View Article and Find Full Text PDFPLoS Med
November 2024
University of Bristol Medical School, Translational Health Sciences, Musculoskeletal Research Unit, Bristol, United Kingdom.
Background: The risk of re-operation, otherwise known as revision, following primary hip replacement depends in part on the prosthesis implant materials used. Current performance evidences are based on a broad categorisation grouping together different materials with potentially varying revision risks. We investigated the revision rate of primary total hip replacement (THR) reported in the National Joint Registry by specific types of bearing surfaces used.
View Article and Find Full Text PDFArthroplast Today
December 2024
Department of Orthopaedic Surgery, University of Washington, Seattle, WA.
Dual-mobility bearings are being increasingly utilized in total hip arthroplasty. Contemporary modular designs often feature inner cobalt-chromium liners that are seated in outer titanium acetabular shells. However, mating of these 2 dissimilar metals may lead to complications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!