Many glaucoma treatments focus on lowering intraocular pressure (IOP), with novel drugs continuing to be developed. One widely used model involves raising IOP by applying a laser to the trabecular iris angle (TIA) of cynomolgus monkeys to damage the trabecular meshwork. This model, however, presents challenges such as varying IOP values, potential trabecular meshwork damage, and risk of animal distress. This study investigated whether animals with naturally high IOP (>25 mmHg) could be used to effectively evaluate IOP-lowering drugs, thereby possibly replacing laser-induced models. Relationships between TIA size, IOP, and pupil diameter were also examined. Three representative IOP-lowering drugs (latanoprost, timolol, ripasudil) were administered, followed by multiple IOP measurements and assessment of corneal thickness, TIA, and pupil diameter via anterior segment optical coherence tomography (AS-OCT). There was a positive correlation was noted between IOP and corneal thickness before instillation, and a negative correlation between IOP and TIA before instillation. Our findings suggest animals with naturally high IOP could be beneficial for glaucoma research and development as a viable replacement for the laser-induced model and that measuring TIA using AS-OCT along with IOP yields a more detailed evaluation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jphs.2023.12.004 | DOI Listing |
Sci Rep
January 2025
Xinqiao Hospital, Army Medical University, 183th, Xinqiao Street, Shapingba District, Chongqing, China.
The purpose of this study was to evaluate the stability of small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) when ascending from near sea level to an altitude of 3874 m. The visual acuity (VA), intraocular pressure (IOP), spherical equivalent refraction (SER) and biometric parameters of 20 normal subjects (40 eyes, controls) and 36 subjects who underwent corneal refractive surgery (35 eyes with SMILE and 36 eyes with LASIK) were examined in Chongqing (C, 500 m above sea level) and 7-10 days after a collective travel to Shigatse (S, 3874 m above sea level). SER and corneal thickness (CT) were choosed as main indicators of the stability of corneal refractive surgery at high altitude.
View Article and Find Full Text PDFPrcis: Trabecular cutting minimally invasive glaucoma surgery like bent ab interno needle goniectomy (BANG) when performed in baseline aqueous angiography identified low aqueous humor outflow regions, results in greater success of intraocular pressure reduction.
Purpose: To study the efficacy of Bent Ab Interno Needle Goniectomy (BANG) in high versus low aqueous humor outflow (AHO) regions as determined by Aqueous Angiography(AA) in patients with primary open angle glaucoma (POAG).
Methods: A prospective, single-centre, pilot, randomized control trial recruited 30 eyes of 30 patients of POAG and visually significant cataract (45-80 y) and were randomised into two groups ("A": BANG performed in the high-flow regions and "B": BANG performed in the low-flow regions) of 15 each.
J Glaucoma
January 2025
Ophthalmology Unit, University Hospital Maggiore della Carità, Novara, Italy.
Prcis: Deep sclerectomy (DS) and canaloplasty provide better intraocular pressure (IOP) control than viscocanalostomy. DS required less glaucoma medications but more interventions to reach target IOP.
Purpose: To compare real-world outcomes of three non-penetrating glaucoma surgery (NPGS) techniques.
PLoS One
January 2025
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Purpose: To investigate the relationship between nocturnal blood pressure (BP) dip and parapapillary choroidal vessel density (pCVD) in patients with normal-tension glaucoma (NTG).
Methods: This study analyzed 267 eyes of 267 untreated NTG patients who underwent 24-hour (h) intraocular pressure (IOP) and ambulatory BP monitoring in the habitual position. Patients were classified into 3 groups [non-dippers (nocturnal BP dip < 10%), dippers (nocturnal BP dip between 10% and 20%, and over-dippers (nocturnal BP dip > 20%)], and pCVDs were measured by using optical coherence tomography angiography (OCTA) images.
Ophthalmol Ther
January 2025
Rocky Vista University, Englewood, CO, USA.
Introduction: This retrospective, consecutive, real-world case series assessed the efficacy and safety of third-generation trabecular micro-bypass stent implantation (iStent infinite) with phacoemulsification in patients with mild-to-moderate primary open-angle glaucoma (POAG).
Methods: Patients underwent phacoemulsification combined with implantation of iStent infinite (containing three stents) by a single U.S.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!