Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Transjugular intrahepatic portosystemic shunt (TIPS) relieves cirrhotic complications by reducing portacaval pressure gradient (PCG), but it lacks precision in achieving a targeted post-TIPS PCG simply through diameter adjustment of equal diameter stents. This study aimed to present a controlled-expansion, streamlined, and covered tapered stent, and examined its effects on pressure reduction compared with equal- diameter stents. Twenty-four patients who underwent standardized 8-mm stent TIPS implantation at West China Hospital from December 2017 to February 2021 were included in the current study. Virtual equal-diameter stent graft with different diameter and streamlined tapered stents were created in the post-TIPS 3-dimentional models reconstructed based on computed tomography angiography data. The numerical simulation showed that only two patients achieved targeted post-TIPS PCG consistent with the clinical invasive measurement. When 6-mm and 10-mm equal-diameter stents were employed, simulated post-TIPS PCGs for most patients remained outside the safe range, and recirculating flow was observed at the stent-portal vein anastomosis. In contrast, the use of the new streamlined taper stent resulted in post-TIPS PCGs within the 10-12 mmHg range for 17 out of 24 patients, with no recirculating flow observed at the anastomotic sites. In conclusion, the streamlined tapered stent could pose an effective solution to the problem that the big jump depressurization between two different equal-diameter stents and it would improve the hemodynamics in the region near the PV-stent anchorage. Therefore, the streamlined tapered stent may present a superior alternative for TIPS procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2024.111937 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!