Purpose: To determine the ability of the photopic negative response (PhNR) of the uniform field electroretinogram (UF-ERG) to identify early glaucomatous changes in comparison to the checkerboard and bar stimuli of the pattern electroretinogram (PERG).
Methods: Forty-nine glaucoma patients were classified into two groups: glaucoma-suspect (23 eyes) and early to moderate glaucoma (30 eyes), based on their clinical examination and the results of standard automated perimetry. Thirty patients (30 eyes) with intraocular pressures (IOP) of 21 mmHg or less, with no history of reported high IOP, were included as controls. PERG and UF-ERG recordings were obtained on a Diagnosys D-341 Attaché-Envoy System. Visual field testing was done only for glaucoma-suspect and glaucoma patients.
Results: All three tests (PERG bar stimulus, PERG checkerboard stimulus and PhNR) displayed significantly prolonged peak times for glaucoma and glaucoma-suspect patients, with delays ranging from 7.8 to 14.8%, depending on the test. The PERG bar stimulus also showed a significantly lower N95 amplitude for both glaucoma groups (with reductions of 26.0% and 33.0% for glaucoma-suspect and glaucoma groups, respectively). The PERG checkerboard N95 amplitude component had high sensitivity for detecting glaucoma patients but a low specificity (97% and 37%, respectively; AUC = 0.61). Overall, the PhNR peak time showed the highest sensitivity and specificity (77% and 90%, respectively; AUC = 0.87).
Conclusions: PERG bar stimuli and the PhNR of the UF-ERG can be used in the clinical setting to detect glaucoma-related changes in glaucoma-suspect and glaucoma patients. However, our data confirm that the PhNR peak time has the best combined sensitivity and specificity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10633-023-09960-9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!