The role of wearable home blood pressure monitoring in detecting out-of-office control status.

Hypertens Res

Cardiovascular Center and Divisions of Cardiology and Hospital Medicine, Department of Internal Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan.

Published: April 2024

Ambulatory blood pressure (ABP) and home blood pressure (HBP) monitoring is currently recommended for management of hypertension. Nonetheless, traditional HBP protocols could overlook diurnal fluctuations, which could also be linked with adverse cardiovascular outcomes. In this observational study, we studied among a group of treated hypertensive patients (N = 62, age: 52.4 ± 10.4 years) by using out-of-office ABP and wearable HBP. They received one session of 24-h ABP measurement with an oscillometric upper-arm monitor, and totally three sessions of 7-day/6-time-daily wearable HBP measurement separated in each month with HeartGuide. Controlled hypertension is defined as an average BP <130/80 mmHg for both daytime ABP and HBP. There was substantial reliability (intraclass correlation coefficient, ICC 0.883-0.911) and good reproducibility (Cohen's kappa = 0.600) for wearable HBP measurement, especially before breakfast and after dinner. Among all patients, 27.4% had both uncontrolled HBP and ABP, 30.6% had uncontrolled HBP only, while 6.5% had uncontrolled ABP only. Female gender and increased numbers of anti-hypertensive agents are correlated with controlled hypertension. Patients with uncontrolled hypertension had a significantly higher maximal daytime blood pressure, which was previously signified as an imperial marker for cardiovascular risk. In conclusion, wearable HBP monitoring in accordance with a dedicated daily-living schedule results in good reliability and reproducibility. Patients with an uncontrolled wearable HBP should benefit from repeated HBP or ABP measurement for risk stratification.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10994837PMC
http://dx.doi.org/10.1038/s41440-023-01539-wDOI Listing

Publication Analysis

Top Keywords

blood pressure
12
wearable hbp
8
role wearable
4
wearable blood
4
pressure monitoring
4
monitoring detecting
4
detecting out-of-office
4
out-of-office control
4
control status
4
status ambulatory
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!