A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Retinal vascular dynamics: A window for observing an irregular heartbeat. A case report. | LitMetric

Objective: We aimed to characterize several aspects of retinal vascular dynamics in a patient with arrythmia in order to elicit additional diagnostic information on microvascular dysfunction.

Methods: A 68-year-old male patient with arrythmia and an age- and gender-matched control subject underwent ocular examination including dynamic retinal vessel assessment with flicker light provocation. Retinal vessel diameters were measured continuously following a standard protocol (IMEDOS Systems, Jena, Germany). The data were evaluated using methods of signal analysis.

Results: Retinal vessel response following flicker provocation as well as local structural and functional behavior of retinal vessels were comparable between both individuals. The arrhythmia case demonstrated irregular arterial and venous heart rate (HR) pulsation with an average frequency of 1 Hz. Moreover, the case showed a higher magnitude and larger periods of low-frequency retinal vessel oscillations as well as lower periodicity of both HR pulsations and low-frequency vasomotions.

Conclusions: Besides numerical examination of irregular HR pulsations in case of arrhythmia, from the direct noninvasive assessment of retinal vessel dynamics one can derive more detailed information on microvascular function including the whole spectrum of retinal arterial and venous pulsations and vasomotions. This may have implications for health screening not limited to atrial fibrillation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/micc.12844DOI Listing

Publication Analysis

Top Keywords

retinal vessel
20
retinal
9
retinal vascular
8
vascular dynamics
8
patient arrythmia
8
arterial venous
8
vessel
5
dynamics window
4
window observing
4
observing irregular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!