The hemodynamics in the aorta as well as the durability of aortic valve prostheses vary greatly between different types of devices. Although placement and sizing of surgical aortic valve prostheses are excellent, the valve geometry of common devices cannot be customized to fit the patient's anatomy perfectly. Similarly, transcatheter aortic valve implantation (TAVI) devices are not customizable and may be orientated unfavorably during implantation. Imperfect fit of an aortic valve prosthesis may result in suboptimal performance and in some cases the need for additional surgery. Leveraging the advent of precision, multi-material 3D-printing, a bioinspired silicone aortic valve was developed. The manufacturing technique makes it fully customizable and significantly cheaper to develop and produce than common prostheses. In this study, we assess the hemodynamic performance of such a 3D-printed aortic valve and compare it to two TAVI devices as well as to a severely stenosed valve. We investigate the blood flow distal to the valve in an anatomically accurate, compliant aorta model via three-dimensional particle tracking velocimetry measurements. Our results demonstrate that the 3D-printed aortic valve induces flow patterns and topology compatible with the TAVI valves and showing similarity to healthy aortic blood flow. Compared to the stenosis, the 3D-printed aortic valve reduces turbulent kinetic energy levels and irreversible energy losses by over 75%, reaching values compatible with healthy subjects and conventional TAVIs. Our study substantiates that the 3D-printed heart valve displays a hemodynamic performance similar to established devices and underscores its potential for driving innovation towards patient specific valve prostheses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10796383PMC
http://dx.doi.org/10.1038/s41598-024-51676-6DOI Listing

Publication Analysis

Top Keywords

aortic valve
36
3d-printed aortic
16
valve
14
blood flow
12
valve prostheses
12
aortic
10
tavi devices
8
hemodynamic performance
8
3d-printed
5
devices
5

Similar Publications

Background: Current guidelines recommend transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis and porcelain aorta (PA). Neurological outcomes of patients with PA undergoing TAVI with modern valves require clarification as most trials examined balloon-expandable valves (BEV) and self-expandable valves in intermediate or high-risk patients, but not specifically in patients with PA. Our aim was to compare outcomes, including stroke and mortality, in well-matched patients with and without PA who received BEV during transfemoral TAVI procedures.

View Article and Find Full Text PDF

Impact of Early Menopause and Hormonal Therapy Replacement on Aortic Stenosis Progression.

Can J Cardiol

January 2025

Institut universitaire de cardiologie et de pneumologie de Québec, Université Laval, Québec city, Québec, Canada. Electronic address:

Background: Early menopause has been associated with several cardiovascular diseases. Its impact on the progression of aortic stenosis (AS) remains unknown. We conducted an analysis to examine the impact of early menopause without hormonal replacement therapy (HRT) on the progression of AS in postmenopausal women with AS.

View Article and Find Full Text PDF

Unveiling the Fourth Dimension: Strain Analysis with Computed Tomography Scans in Transcatheter Aortic Valve Replacement Innovation.

Can J Cardiol

January 2025

Division of Cardiology, Department of Medicine, University of Toronto, Toronto, Canada; Division of Cardiology, Terrence Donnelly Heart Centre, St Michael's Hospital, 30 Bond Street, Toronto, Canada; Keenan Research Centre, Li Ka Shing Knowledge Institute, St Michael's Hospital, Toronto, Canada.

View Article and Find Full Text PDF

Introduction: Aortic stenosis (AS) and pulmonic stenosis (PS) are two of the most common canine congenital heart diseases (CHD), with a high relative risk for Newfoundland dogs to develop inherited subvalvular AS. For this reason, a cardiovascular screening program has been set up by the French Newfoundland kennel club in order to manage mattings and reduce AS prevalence.

Materials And Methods: The records of untreated and non-anesthetized adult Newfoundland dogs screened between 2010 and 2023 were retrospectively reviewed.

View Article and Find Full Text PDF

This study aims to evaluate the implementation of concomitant CAD assessment on pre-TAVI (transcatheter aortic valve implantation) planning CTA (CT angiography) aided by CT-FFR (CT-fractional flow reserve) [The CT2TAVI protocol] and investigates the incremental value of CT-FFR to coronary CT angiography (CCTA) alone in the evaluation of patients undergoing CT2TAVI. This is a prospective observational real-world cohort study at an academic health system on consecutive patients who underwent CTA for TAVI planning from 1/2021 to 6/2022. This represented a transition period in our health system, from not formally reporting CAD on pre-TAVI planning CTA (Group A) to routinely reporting CAD on pre-TAVI CTA (Group B; CT2TAVI protocol).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!