Evaluation of Antibacterial Effect of New Sealer "Neoseal" and Two Commercially Used Endodontic Sealers against : An Study.

J Contemp Dent Pract

Department of Fixed Prosthodontics, Faculty of Dentistry, Ahram Canadian University, Egypt, Phone: +20 1288670943, e-mail:

Published: November 2023

Aim: To evaluate the antibacterial activity of three endodontic sealing materials, Neoseal, CeraSeal, and AH Plus against bacteria .

Materials And Methods: The antibacterial activity of three endodontic sealing materials including two bioceramic sealers; NeoSEALER Flo (group I), CeraSeal (group II), and one epoxy resin sealer; AH Plus (group III) was investigated against bacteria American Type Cell Culture Collection (ATCC) 29212 (ATCC, Rockville, Maryland, USA). Using modified direct contact test (MDCT). The endodontic sealers were tested in contact with bacterial suspension when unset (20 minutes after mixing) and after setting, assessing the antibacterial activity of aged sealers after 1, 3, 7, and 14 days. Analyzing the collected data has been done with version 25.0 of the statistical package for the social sciences (SPSS) IBM software (SPSS, Chicago, Illinois, USA). Descriptive analyses were calculated using standard deviation (SD) and mean. Shapiro-Wilk test was done to detect the normality of the result values. Kruskal-Wallis test was then performed to test the level of significance between groups.

Results: After 20 minutes - Group I showed higher bacterial count mean values (5,500 ± 500) and 0 values for groups II and III groups. After 1 day, the highest bacterial count mean values were in group III (54,333.3 ± 4,041.5) and 0 values for groups I and II. After 3 days - group III again recorded the highest bacterial count mean values (45,000 ± 5,000) and 0 values for I and II groups. After 7 days - Group III still recorded the highest bacterial count mean values (53,333.3 ± 1,527.5) and 0 values for groups I and II. After 14 days - Group III recorded the highest bacterial count mean values (56,000 ± 1,000) followed by group II (6,333.3 ± 577.4), and the least was group I (2,000 ± 500). Kruskal-Wallis test showed significant values between groups in all tested durations, > 0.05.

Conclusion: The sealing material AH Plus showed a strong bactericidal effect at the beginning but lost its ability after 24 hours. CeraSeal showed strong bactericidal activity from the beginning till the end of the first week but showed bacterial count at 14 days. Neoseal took 24 hours to show bactericidal effect and similar to CeraSeal showed bacterial count at 14 days; CeraSeal recorded the best results within the study.

Clinical Significance: Silicate-based (bioceramic) endodontic sealers can be the best available endodontic sealing material that is clinically beneficial in removing residual microbes which had survived irrigation protocols and chemomechanical preparation. How to cite this article: Basta DG, Reslan MR, Rayyan M, . Evaluation of Antibacterial Effect of New Sealer "Neoseal" and Two Commercially Used Endodontic Sealers against : An Study. J Contemp Dent Pract 2023;24(11):871-876.

Download full-text PDF

Source
http://dx.doi.org/10.5005/jp-journals-10024-3599DOI Listing

Publication Analysis

Top Keywords

bacterial count
28
group iii
20
count values
20
values groups
20
endodontic sealers
16
highest bacterial
16
antibacterial activity
12
endodontic sealing
12
groups days
12
days group
12