W-Net: A boundary-aware cascade network for robust and accurate optic disc segmentation.

iScience

School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.

Published: January 2024

AI Article Synopsis

  • * This study introduces a multi-level segmentation network comprising modules for data quality enhancement, coarse and fine segmentation, and localization, with a novel W-Net and boundary loss in the fine segmentation stage.
  • * The proposed model demonstrated superior optic disc segmentation performance across multiple datasets, outperforming existing state-of-the-art methods.

Article Abstract

Accurate optic disc (OD) segmentation has a great significance for computer-aided diagnosis of different types of eye diseases. Due to differences in image acquisition equipment and acquisition methods, the resolution, size, contrast, and clarity of images from different datasets show significant differences, resulting in poor generalization performance of deep learning networks. To solve this problem, this study proposes a multi-level segmentation network. The network includes data quality enhancement module (DQEM), coarse segmentation module (CSM), localization module (OLM), and fine segmentation stage module (FSM). In FSM, W-Net is proposed for the first time, and boundary loss is introduced in the loss function, which effectively improves the performance of OD segmentation. We generalized the model in the REFUGE test dataset, GAMMA dataset, Drishti-GS1 dataset, and IDRiD dataset, respectively. The results show that our method has the best OD segmentation performance in different datasets compared with state-of-the-art networks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10790032PMC
http://dx.doi.org/10.1016/j.isci.2023.108247DOI Listing

Publication Analysis

Top Keywords

accurate optic
8
optic disc
8
disc segmentation
8
segmentation
7
w-net boundary-aware
4
boundary-aware cascade
4
cascade network
4
network robust
4
robust accurate
4
segmentation accurate
4

Similar Publications

This study presents a patient with a PET-CT detected residual lacrimal sac tumor who was treated with intensity modulated proton therapy (IMPT) and concurrent chemotherapy. The patient a 49-year-old male diagnosed with squamous cell carcinoma of the left lacrimal sac had under-went endoscopic surgery. Postoperative PET-CT implied tumor residual in the left lacrimal sac.

View Article and Find Full Text PDF

Liquid crystals (LC) are widely used in various optical devices due to their birefringence, dielectric anisotropy, and responsive behavior to external fields. Enhancing the properties of existing LCs through doping with nanoparticles, including semiconductor quantum dots, offers a promising route for improving their performance. Among various nanoparticles, QDs stand out for their high charge mobility, sensitivity in the near-infrared spectral region, and cost-effectiveness.

View Article and Find Full Text PDF

Single-Injection Composite Tracer Achieves Intraoperative Dual-Tracing and Precise Localization of Sentinel Lymph Nodes.

ACS Appl Mater Interfaces

January 2025

Sixth People's Hospital, School of Medicine & School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, P. R. China.

The use of dual-tracer contrast agents in clinical applications, such as sentinel lymph node (SLN) identification, offers significant advantages including enhanced accuracy, sensitivity, as well as comprehensive and multimodal visualization. In the current clinical practice, SLNs are typically marked prior to surgical resection by multiple and sequential injections of two tracers, the radioactive tracer and methylene blue (MB) dye. This imposes physical and psychological burden on patients and medical staff.

View Article and Find Full Text PDF

Widespread screening is crucial for the early diagnosis and treatment of glaucoma, the leading cause of visual impairment and blindness. The development of portable technologies, such as smartphone-based ophthalmoscopes, able to image the optical nerve head, represents a resource for large-scale glaucoma screening. Indeed, they consist of an optical device attached to a common smartphone, making the overall device cheap and easy to use.

View Article and Find Full Text PDF

MXene-based SERS spectroscopic analysis of exosomes for lung cancer differential diagnosis with deep learning.

Biomed Opt Express

January 2025

Key Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, University of Shanghai for Science and Technology, 200093 Shanghai, China.

Lung cancer with heterogeneity has a high mortality rate due to its late-stage detection and chemotherapy resistance. Liquid biopsy that discriminates tumor-related biomarkers in body fluids has emerged as an attractive technique for early-stage and accurate diagnosis. Exosomes, carrying membrane and cytosolic information from original tumor cells, impart themselves endogeneity and heterogeneity, which offer extensive and unique advantages in the field of liquid biopsy for cancer differential diagnosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!