The evaluation of high-speed camera image sequence analysis results in concrete material testing under high-impact loading necessitates the consideration of the effect of the image quality on the measurement accuracy and thus on the potential of the geometric measurements derived from the image sequences. In this contribution, we evaluate the application potential of three ultrahigh-speed cameras with frame rates up to 10 Mfps to analyze the deformation of concrete specimens before and after main crack formation in bending and compression tests. Specifically, we evaluate the Kirana 7M and Shimadzu HPV-X2 cameras with ISIS sensor architecture, and the Phantom TMX 7510 camera with BSI CMOS sensor technology. Three-point bending tests and split-Hopkinson pressure bar tests are performed on 160×40×40 cuboids and on 80 mm long, 50 mm diameter cylinders. Prior to main crack formation, the displacement vector field represents the specimen deformation, with higher values indicating the position where main cracks will initiate and propagate. Deformations of 80 µm in 54 µs for a bending test and of 154 µm in 36.67 µs for a compression test could be measured. The main cracks are then detected using displacement vector field discontinuity analysis techniques, and their evolution is followed to estimate the crack propagation velocity. Average velocities in bending tests between 603 and 854 m/s have been determined over a time interval up to 40 µs. An investigation of the camera sensor operation of the three optical devices is presented to assess their suitability for deformation analysis. Laboratory tests and real experimental results show that the quality of the propagation vector field, the crack detection, and the crack tip tracking are obviously affected by the image quality, but more significantly by the spatial and temporal resolution due to the small relative step deformations.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.506701DOI Listing

Publication Analysis

Top Keywords

vector field
12
deformation analysis
8
image quality
8
main crack
8
crack formation
8
bending tests
8
displacement vector
8
main cracks
8
crack
5
tests
5

Similar Publications

Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.

View Article and Find Full Text PDF

Background: Leishmaniasis is a health problem in many regions with poor health and poor life resources. According to the World Health Organization (WHO), an estimated 700,000-1 million new cases arise annually. Effective control of sand fly vector populations is crucial for reducing the transmission of this disease.

View Article and Find Full Text PDF

Attosecond Rescattering of Laser-Assisted Electron-Proton Collision in Coulomb Potential.

J Phys Chem A

January 2025

Department of Chemistry, University of Malaya, 50603 Kuala Lumpur, Malaysia.

This study investigates the motion of an electron in a Coulomb potential driven by an intense linearly polarized XUV laser pulse analyzed using Gordon-Volkov wave functions. The wave function is decomposed into spherical partial waves to model the scattered electron wave packet after the recollision with a proton. This interaction triggers high harmonic generation, producing coherent X-ray pulses with frequencies that are integer multiples of the XUV field.

View Article and Find Full Text PDF

Introduction: The study of attention has been pivotal in advancing our comprehension of cognition. The goal of this study is to investigate which EEG data representations or features are most closely linked to attention, and to what extent they can handle the cross-subject variability.

Methods: We explore the features obtained from the univariate time series from a single EEG channel, such as time domain features and recurrence plots, as well as representations obtained directly from the multivariate time series, such as global field power or functional brain networks.

View Article and Find Full Text PDF

Chimeric antigen receptor T-cell (CAR-T) therapy is a revolutionary approach in cancer treatment. More than 10 CAR-T products have already approved on market worldly wide, and they use either gamma retroviral vectors or lentiviral vectors to deliver the CAR gene. Both vectors have the ability to effectively and persistently integrate the CAR gene into T cells.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!