  • The incidence of osteoporotic distal humeral fractures (DHF) is increasing, and traditional fixation methods have high complication rates, leading to consideration of elbow arthroplasty despite its limitations.
  • A study examining patients aged 75 and older who underwent double plating with locking plates for type C3 DHF found that this method resulted in all fractures healing successfully, with no cases of revision surgery or loss of reduction.
  • However, there was a significant complication rate (40%), primarily involving ulnar neuropathy, highlighting that while the procedure is effective, some complications are still likely.

Article Abstract

Introduction: The incidence of osteoporotic distal humeral fractures (DHF) is on the rise. Their operative management is demanding. Fixation with non-locking reconstruction plates was associate with a high number of complications. Elbow arthroplasty (total or hemi) has been proposed as an alternative treatment, in spite of lifetime activity restrictions, and risk of complications, unknown implant survival and problematic revision surgery. Precontoured anatomical locking plates have increased the strength of the fixation in complex fractures.

Hypothesis: double plating ORIF with precontoured anatomical locking plates is a safe and reliable treatment option for the management of AO/OTA type C3 DHF in patients aged 75 and older.

Patients And Methods: A retrospective case series study of patients aged 75 years old and older with an AO/OTA type C3 DHF treated with ORIF with double precontoured anatomical locking plates between 2007 and 2021. Pathologic fractures were excluded. Patients' demographic, surgical, clinical, and radiological data were reviewed.

Results: A total of 27 women and 3 men, mean age of 80.1 years (range 75-93 years), were included. Mean Charlson index was 5 (range 3-8). Out of 30 patients, 19 had already died. Mean survival time after the surgical treatment was 72.3 months. Mean Mayo elbow performance score was 88.9 (range 60-100); 23 patients scored excellent or good. All fractures healed with no cases of delay union or non-union, hardware failure or loss of reduction. No patient needed a revision surgery to arthroplasty. The total number of complications was 12 (40%), mainly ulnar neuropathy (5) and cerclage removal (4).

Conclusion: ORIF with double pre-contoured locking plates may be a safe and reliable treatment for type C3 DHF in patients aged 75 years and older, with a good functional outcome. Complications are expected but not related to loss of reduction, fixation failure or revision to elbow arthroplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2023.111043DOI Listing

Publication Analysis

Top Keywords

locking plates
20
patients aged
16
precontoured anatomical
16
anatomical locking
16
ao/ota type
12
aged years
12
years older
12
orif double
12
type dhf
12
distal humeral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!