Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The failure rate of orthodontic mini-screws depends strongly on primary stability and, thus, on insertion torque. Further improvement regarding the failure rate might be achieved by modifying the surface coating. Therefore, the aim of the study was to investigate the stability of a newly designed and surface-modified orthodontic mini-screw in beagle dogs.
Methods: Newly designed mini-screws coated either with DOTIZE® or DOTIZE®-copper (DOT GmbH, Rostock, Germany; each: n = 24) were inserted in the mandibles of eight beagle dogs for a duration of 8 months. Insertion and removal torque were measured. These data were compared to values generated by using the artificial bone material Sawbones® (Sawbones Europe AB, Malmö, Sweden). Experiments with and without torque limitation (each: n = 5) were run. The bone-to-implant contact rate and the amount of bone between the threads were examined. Statistical significance was set at P < 0.05.
Results: The success rates of the in vivo study reached high levels with 95.3% for the DOTIZE-coated and 90.5% for the DOTIZE-copper-coated screws, whereas the insertion and removal torque did not differ between the coatings. During insertion, a torque limitation of 20 Ncm was necessary to ensure that the recommended limit was not exceeded. The insertion in Sawbones without torque limitation revealed a significantly higher torque compared to torque-limited insertion (18.2 ± 1.3 Ncm, 23.6 ± 1.3 Ncm). Bending occurred (n = 5) in the thread-free part of the mini-screw.
Conclusions: Surface coating might be able to improve the performance of orthodontic mini-screws. The study showed high success rates and stable mini-screws until the end of observation. Further investigations are necessary.