The effect of enhanced structure in the posterior segment of clear aligners during anterior retraction: a three-dimensional finite element and experimental model analysis.

Prog Orthod

State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, 14# 3Rd Section of Ren Min Nan Road, Chengdu, 610041, Sichuan Province, China.

Published: January 2024

Background: Mesial tipping of posterior teeth occurs frequently during space closure with clear aligners (CAs). In this study, we proposed a new modification of CA by localized thickening of the aligner to form the enhanced structure and investigate its biomechanical effect during anterior retraction.

Methods: Two methods were employed in this study. First, a finite element (FE) model was constructed, which included alveolar bone, the first premolars extracted maxillary dentition, periodontal ligaments (PDL), attachments and aligners. The second method involved an experimental model-a measuring device using multi-axis transducers and vacuum thermoforming aligners. Two groups were formed: (1) The control group used common CAs and (2) the enhanced structure group used partially thickened CAs.

Results: FE model revealed that the enhanced structure improved the biomechanics during anterior retraction. Specifically, the second premolar, which had a smaller PDL area, experienced a smaller protraction force and moment, making it less likely to tip mesially. In the same vein, the molars could resist movement due to their larger PDL area even though they were applied larger forces. The resultant force of the posterior tooth was closer to the center of resistance, reducing the tipping moment. The canine was applied a larger retraction force and moment, resulting in sufficient retraction of anterior teeth. The experimental model demonstrated a similar trend in force variation as the FE model.

Conclusions: Enhanced structure allowed force distribution more in accordance with optimal principles of biomechanics during the extraction space closure while permitting less mesial tipping and anchorage loss of posterior teeth and better retraction of anterior teeth. Thus, enhanced structure alleviated the roller coaster effect associated with extraction cases and offered a new possibility for anchorage reinforcement in clear aligner therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10788328PMC
http://dx.doi.org/10.1186/s40510-023-00502-2DOI Listing

Publication Analysis

Top Keywords

enhanced structure
24
clear aligners
8
anterior retraction
8
finite element
8
experimental model
8
mesial tipping
8
posterior teeth
8
space closure
8
pdl area
8
force moment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!