A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monolith-coated microcentrifuge tubes for the easy extraction of psychoactive substances from urine samples and liquid chromatography-tandem mass spectrometry determination. | LitMetric

Background: Sample extraction is one of the most critical steps in most of the analytical processes. Nowadays, there is a demand for simple approaches that can effectively extract and concentrate target analytes from complex matrices, like biofluids, with accurate and reliable results.

Results: A porous monolith of poly(methacrylic acid-co-ethylene glycol dimethacrylate) has been immobilized on the inner wall of a 2 mL commercial polypropylene microcentrifuge tube through radical photopolymerization, using bis(2,4,6-trimethylbenzoyl)phenylphosphine oxide as radical initiator and 405 nm laser pointer activation. Photopolymerization parameters were adjusted to obtain a continuous and homogeneous polymer layer (0.16 mm wet polymer thickness and 31 mg dry polymer weight) in the inner tube surface. Extraction efficiency of twelve psychoactive substances was assessed by the evaluation of the effect of sample pH, extraction and desorption times, and desorption solvent volume. Moreover, matrix effect, reusability and stability of monolith-coated microcentrifuge tubes were studied. Sample extracts were measured by liquid chromatography-tandem mass spectrometry, providing limits of quantification (LOQ) from 0.2 to 2.7 μg L, recoveries from 80 to 118 %, relative standard deviations lower than 17 %, and a linear range from LOQ to 500 μg L.

Significance: The proposed device is suitable for the easy and simple extraction of psychoactive substances from urine samples with a high portability, reduced solvent consumption, low cost, and low environmental impact.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2023.342136DOI Listing

Publication Analysis

Top Keywords

psychoactive substances
12
monolith-coated microcentrifuge
8
microcentrifuge tubes
8
extraction psychoactive
8
substances urine
8
urine samples
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
sample extraction
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!