Enhanced deep learning model enables accurate alignment measurement across diverse institutional imaging protocols.

Knee Surg Relat Res

Department of Orthopaedic Surgery, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 110-744, Republic of Korea.

Published: January 2024

Background: Achieving consistent accuracy in radiographic measurements across different equipment and protocols is challenging. This study evaluates an advanced deep learning (DL) model, building upon a precursor, for its proficiency in generating uniform and precise alignment measurements in full-leg radiographs irrespective of institutional imaging differences.

Methods: The enhanced DL model was trained on over 10,000 radiographs. Utilizing a segmented approach, it separately identified and evaluated regions of interest (ROIs) for the hip, knee, and ankle, subsequently integrating these regions. For external validation, 300 datasets from three distinct institutes with varied imaging protocols and equipment were employed. The study measured seven radiologic parameters: hip-knee-ankle angle, lateral distal femoral angle, medial proximal tibial angle, joint line convergence angle, weight-bearing line ratio, joint line obliquity angle, and lateral distal tibial angle. Measurements by the model were compared with an orthopedic specialist's evaluations using inter-observer and intra-observer intraclass correlation coefficients (ICCs). Additionally, the absolute error percentage in alignment measurements was assessed, and the processing duration for radiograph evaluation was recorded.

Results: The DL model exhibited excellent performance, achieving an inter-observer ICC between 0.936 and 0.997, on par with an orthopedic specialist, and an intra-observer ICC of 1.000. The model's consistency was robust across different institutional imaging protocols. Its accuracy was particularly notable in measuring the hip-knee-ankle angle, with no instances of absolute error exceeding 1.5 degrees. The enhanced model significantly improved processing speed, reducing the time by 30-fold from an initial 10-11 s to 300 ms.

Conclusions: The enhanced DL model demonstrated its ability for accurate, rapid alignment measurements in full-leg radiographs, regardless of protocol variations, signifying its potential for broad clinical and research applicability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10785531PMC
http://dx.doi.org/10.1186/s43019-023-00209-yDOI Listing

Publication Analysis

Top Keywords

institutional imaging
12
imaging protocols
12
alignment measurements
12
enhanced model
12
deep learning
8
learning model
8
measurements full-leg
8
full-leg radiographs
8
hip-knee-ankle angle
8
angle lateral
8

Similar Publications

Background: For radiotherapy of head and neck cancer (HNC) magnetic resonance imaging (MRI) plays a pivotal role due to its high soft tissue contrast. Moreover, it offers the potential to acquire functional information through diffusion weighted imaging (DWI) with the potential to personalize treatment. The aim of this study was to acquire repetitive DWI during the course of online adaptive radiotherapy on an 1.

View Article and Find Full Text PDF

True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.

View Article and Find Full Text PDF

Background: Fibrotic types of interstitial lung abnormalities seen on high-resolution computed tomography scans, characterised by traction bronchiolectasis/bronchiectasis with or without honeycombing, are predictors of progression and poor prognostic factors of interstitial lung abnormalities. There are no reports on the clinical characteristics of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans. Therefore, we aimed to examine these clinical characteristics and clarify the predictive factors of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans.

View Article and Find Full Text PDF

Background: To compare the effects of first premolar extraction, molar distalization, and non-extraction treatments on the angulation and vertical positions of maxillary second molars (MxM2s) and maxillary third molars (MxM3s). To our knowledge, this is the first study to compare the effects of three different treatment types on MxM3 simultaneously.

Methods: Initial (T0) and final (T1) panoramic radiographs of three different patient groups were analyzed: first premolar extraction group (n = 26 patients, 52 MxM2, 52 MxM3), molar distalization group (n = 20 patients, 40 MxM2, 40 MxM3), and non-extraction group (n = 31 patients, 62 MxM2, 62 MxM3).

View Article and Find Full Text PDF

With the progress of atherosclerosis (AS), the arterial lumen stenosis and compact plaque structure, the thickening intima and the narrow gaps between endothelial cells significantly limit the penetration efficiency of nanoprobe to plaque, weakening the imaging sensitivity and therapy efficiency. Thus, in this study, a HO-NIR dual-mode nanomotor, Gd-doped mesoporous carbon nanoparticles/Pt with rapamycin (RAPA) loading and AntiCD36 modification (Gd-MCNs/Pt-RAPA-AC) was constructed. The asymmetric deposition of Pt on Gd-MCNs catalyzed HO at the inflammatory site to produce O, which could promote the self-motion of the nanomotor and ease inflammation microenvironment of AS plaque.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!