We consider properties of dichroic antenna arrays on a silicon substrate with integrated cold-electron bolometers to detect radiation at frequencies of 210 and 240 GHz. This frequency range is widely used in cosmic microwave background experiments in space, balloon, and ground-based missions such as BICEP Array, LSPE, LiteBIRD, QUBIC, Simons Observatory, and AliCPT. As a direct radiation detector, we use cold-electron bolometers, which have high sensitivity and a wide operating frequency range, as well as immunity to spurious cosmic rays. Their other advantages are the compact size of the order of a few micrometers and the effect of direct electron cooling, which can improve sensitivity in typical closed-loop cycle He cryostats for space applications. We study a novel concept of cold-electron bolometers with two SIN tunnel junctions and one SN contact. The amplitude-frequency characteristics measured with YBCO Josephson Junction oscillators show narrow peaks at 205 GHz for the 210 GHz array and at 225 GHz for the 240 GHz array; the separation of these two frequency bands is clearly visible. The noise equivalent power level at an operating point in the current bias mode is 5 × 10 W/√Hz.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10777328 | PMC |
http://dx.doi.org/10.3762/bjnano.15.3 | DOI Listing |
Beilstein J Nanotechnol
January 2024
Dipartimento di Fisica, Università La Sapienza, I-00185 Roma, Italy.
We consider properties of dichroic antenna arrays on a silicon substrate with integrated cold-electron bolometers to detect radiation at frequencies of 210 and 240 GHz. This frequency range is widely used in cosmic microwave background experiments in space, balloon, and ground-based missions such as BICEP Array, LSPE, LiteBIRD, QUBIC, Simons Observatory, and AliCPT. As a direct radiation detector, we use cold-electron bolometers, which have high sensitivity and a wide operating frequency range, as well as immunity to spurious cosmic rays.
View Article and Find Full Text PDFBeilstein J Nanotechnol
September 2022
Nizhny Novgorod State Technical University, Nizhny Novgorod, Minin Street, 24, 603950, Russia.
Electron on-chip cooling from the base temperature of 300 mK is very important for highly sensitive detectors operating in space due to problems of dilution fridges at low gravity. Electron cooling is also important for ground-based telescopes equipped with He cryostats being able to function at any operating angle. This work is aimed at the investigation of electron cooling in the low-temperature range.
View Article and Find Full Text PDFBeilstein J Nanotechnol
September 2022
Nizhny Novgorod State Technical University, Nizhny Novgorod, Minin Street, 24, 603950, Russia.
Here we present the results of a numerical modeling of mode composition in the constriction of the Large Scale Polarization Explorer-Short-Wavelength Instrument for the Polarization Explorer (LSPE-SWIPE) back-to-back horn. These results are used for calculating the frequency response of arrays of planar dipole antennas with cold-electron bolometers for 145, 210, and 240 GHz frequencies. For the main frequency channel (i.
View Article and Find Full Text PDFSci Rep
December 2020
Nizhny Novgorod State Technical University n.a. R.E. Alekseev, GSP-41, Nizhny Novgorod, 603950, Russia.
The Cosmic Microwave Background (CMB) radiation is the only observable that allows studying the earliest stage of the Universe. Radioastronomy instruments for CMB investigation require low working temperatures around 100 mK to get the necessary sensitivity. On-chip electron cooling of receivers is a pathway for future space missions due to problems of dilution fridges at low gravity.