Background: Cardiovascular Magnetic Resonance (CMR) native T1 and T2 mapping serve as robust, contrast-agent-free diagnostic tools, but hardware- and software-specific sources of variability limit the generalizability of data across CMR platforms, consequently limiting the interpretability of patient-specific parametric data. Z-scores are used to describe the relationship of observed values to the mean results as obtained in a sufficiently large normal sample. They have been successfully used to describe the severity of quantifiable abnormalities in medicine, specifically in children and adolescents. The objective of this study was to observe whether z-scores can improve the comparability of T1 and T2 mapping values across CMR scanners, field strengths, and sequences from different vendors in the same participant rather than different participants (as seen in previous studies).
Methods: Fifty-one healthy volunteers (26 men/25 women, mean age = 43 ± 13.51) underwent three CMR exams on three different scanners, using a Modified Look-Locker Inversion Recovery (MOLLI) 5-(3)- 3 sequence to quantify myocardial T1. For T2 mapping, a True Fast Imaging with steady-state free precession (TRUFI) sequence was used on a 3 T Skyra™ (Siemens), and a T2 Fast Spin Echo (FSE) sequence was used on 1.5 T Artist™ (GE) and 3.0 T Premier™ (GE) scanners. The averages of basal and mid-ventricular short axis slices were used to derive means and standard deviations of global mapping values. We used intra-class comparisons (ICC), repeated measures ANOVA, and paired Student's t-tests for statistical analyses.
Results: There was a significant improvement in intra-subject comparability of T1 (ICC of 0.11 (95% CI= -0.018, -0.332) vs 0.78 (95% CI= 0.650, 0.866)) and T2 (ICC of 0.35 (95% CI= -0.053, 0.652) vs 0.83 (95% CI= 0.726, 0.898)) when using z-scores across all three scanners. While the absolute global T1 and T2 values showed a statistically significant difference between scanners (p < 0.001), no such differences were identified using z-scores (T1: p = 0.771; T2: p = 0.985). Furthermore, when images were not corrected for motion, T1 z-scores showed significant inter-scanner variability (p < 0.001), resolved by motion correction.
Conclusion: Employing z-scores for reporting myocardial T1 and T2 removes the variation of quantitative mapping results across different MRI systems and field strengths, improving the clinical utility of myocardial tissue characterization in patients with suspected myocardial disease.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11211228 | PMC |
http://dx.doi.org/10.1016/j.jocmr.2023.100004 | DOI Listing |
JAMA Cardiol
January 2025
Center for Health Incentives and Behavioral Economics, University of Pennsylvania, Philadelphia.
Importance: A comprehensive lipid panel is recommended by guidelines to evaluate atherosclerotic cardiovascular disease risk, but uptake is low.
Objective: To evaluate whether direct outreach including bulk orders with and without text messaging increases lipid screening rates.
Design, Setting, And Participants: Pragmatic randomized clinical trial conducted from June 6, 2023, to September 6, 2023, at 2 primary care practices at an academic health system among patients aged 20 to 75 years with at least 1 primary care visit in the past 3 years who were overdue for lipid screening.
JAMA
January 2025
Division of General Internal Medicine and Geriatrics, Indiana University School of Medicine, Indianapolis.
Importance: Care management benefits community-dwelling patients with dementia, but studies include few patients with moderate to severe dementia or from racial and ethnic minority populations, lack palliative care, and seldom reduce health care utilization.
Objective: To determine whether integrated dementia palliative care reduces dementia symptoms, caregiver depression and distress, and emergency department (ED) visits and hospitalizations compared with usual care in moderate to severe dementia.
Design, Setting, And Participants: A randomized clinical trial of community-dwelling patients with moderate to severe dementia and their caregivers enrolled from March 2019 to December 2020 from 2 sites in central Indiana (2-year follow-up completed on January 7, 2023).
JAMA Cardiol
January 2025
Ifakara Health Institute, Ifakara Branch, Ifakara, United Republic of Tanzania.
Importance: Hypertension is the primary cardiovascular risk factor in Africa. Recently revised World Health Organization guidelines recommend starting antihypertensive dual therapy; clinical efficacy and tolerability of low-dose triple combination remain unclear.
Objectives: To compare the effect of 3 treatment strategies on blood pressure control among persons with untreated hypertension in Africa.
JAMA Netw Open
January 2025
Department of Pediatrics, The Children's Hospital at Montefiore, Albert Einstein College of Medicine, Bronx, New York.
Importance: Pediatric obesity and hypertension are highly correlated. To mitigate both conditions, provision of counseling on nutrition, lifestyle, and weight to children with high blood pressure (BP) measurements is recommended.
Objective: To examine racial and ethnic disparities in receipt of nutrition, lifestyle, and weight counseling among patients with high BP at pediatric primary care visits stratified by patients' weight status.
JAMA Netw Open
January 2025
Department of Medicine, University of California, San Francisco.
Importance: Multiple organ dysfunction (MOD) is a leading cause of in-hospital child mortality. For survivors, posthospitalization health care resource use and costs are unknown.
Objective: To evaluate longitudinal health care resource use and costs after hospitalization with MOD in infants (aged <1 year) and children (aged 1-18 years).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!