A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validating the Reliability and Clinical Relevance of a Nasolabial Fold Photonumeric Scale. | LitMetric

Background: The use of tissue fillers to treat age-related deepening of the nasolabial fold (NLF) has increased and become the standard clinical approach, creating a need for evidence-based, objective evaluation for pre- and post-procedure assessment of the NLF.

Methods: A 5-point rating scale was developed to assess the NLF, specifically the presence of depression and shadowing. Live validation of the scale was performed with a total of 73 participants representing the full range of NLF severities. Physicians board-certified in a core aesthetic specialty (3 trained raters) performed the scale validation over 2 rounds, 2 weeks apart. Training was carried out, and test-retest reliability was quantitated through the determination of intra- and inter-rater reliability by percentage of agreement, weighted kappa statistic with 95% confidence interval (CI), and intraclass correlation coefficient with 95% CI. To evaluate the clinical relevance of a 1-grade difference, rater assessments of 90 photo pairs were compared with previous designations of clinically different or not clinically different.

Results: The NLF scale achieved near-perfect intra- and inter-rater reliability when utilized by trained raters to assess a diverse group of live participants. Furthermore, clinically relevant differences between grades were established, and a 1-point difference was detectable by trained evaluators using the NLF scale.

Conclusion: The clinically relevant and highly reliable validated NLF scale provides a standardized grading system with a user-friendly design for objectively assessing NLF in clinical practice and as a research tool for clinical approval studies of new aesthetic products and technologies. J Drugs Dermatol. 2024;23(1):1284-1291.   doi:10.36849/JDD.7316.

Download full-text PDF

Source
http://dx.doi.org/10.36849/JDD.7316DOI Listing

Publication Analysis

Top Keywords

clinical relevance
8
nasolabial fold
8
trained raters
8
intra- inter-rater
8
inter-rater reliability
8
nlf scale
8
clinically relevant
8
nlf
7
scale
6
clinical
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!