A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Increase in gap index over time after reduction of unstable paediatric both-bone forearm fracture does not cause displacement. | LitMetric

This study investigated the effects of changes in the gap index on fracture displacement during follow-up. Patients who underwent closed reduction and casting with a diagnosis of unstable paediatric both-bone forearm fractures and a cast index < 0.8 were retrospectively evaluated. Patients were divided into Groups 1 and 2 based on their gap index (<0.15 and >0.15, respectively). Anteroposterior and lateral displacements of the radius and ulna and the gap index of the cast were measured on the X-ray after the first reduction and on the last X-ray before plaster removal. The mean patient age (n = 94, 74 boys and 20 girls; 51 in Group 1 and 43 in Group 2) was 7.09 ± 2.66 years. Fracture union times (plaster removal) were 38.8 ± 7.1 days. The mean cast index was 0.76 ± 0.05 (0.59-0.8). Both groups had similar distributions in terms of age, sex, fracture side, anatomic location and plaster removal time (p > 0.05). No significant differences were observed in either group in any radial or ulnar angulation values at any time point or the difference between the first and last values (all p > 0.05). Moreover, the gap index difference between the first and last measurements was significantly different in both groups (p = 0.002). If the cast index remains <0.8, despite the increase in the gap index in both groups, the amount of fracture displacement was small and acceptable.

Download full-text PDF

Source
http://dx.doi.org/10.52628/89.4.11650DOI Listing

Publication Analysis

Top Keywords

plaster removal
12
unstable paediatric
8
paediatric both-bone
8
both-bone forearm
8
fracture displacement
8
increase gap
4
gap time
4
time reduction
4
reduction unstable
4
fracture
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!