Objective: To review the current recommendations on postoperative precautions for obstructive sleep apnoea patients undergoing elective nasal surgery.
Design: Retrospective cohort study.
Setting: Department of Otorhinolaryngology and Anesthesiology/Intensive Care, University Teaching Hospital, Rotterdam, the Netherlands.
Participants: The medical charts of 61 patients with sleep apnoea who were admitted to the post-anaesthesia care unit between 2016 and 2020, following nasal surgery were reviewed.
Main Outcome Measures: Number of respiratory events during post-anaesthesia care unit admission that required medical intervention.
Results: In all 61 patients, continuous positive airway pressure could not be used. In 13 patients (8%), decreased oxygen saturation levels were registered during the first postoperative night, and in five of these patients, supplemental oxygen was needed. No other respiratory incidents of medical interventions were registered.
Conclusions: The number of clinically relevant respiratory events of obstructive sleep apnoea patients with bilateral nasal packing following nasal surgery is low. We suggest that the safety of less expensive and less scarce alternatives of postoperative observation should be explored.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/17504589231215941 | DOI Listing |
Barbed reposition pharyngoplasty (BRP) is a new technique to manage velo-pharyngeal obstruction and collapse in OSA patients. Tonsillectomy is a preliminary step of BRP surgery. Dissection of the PPM with monopolar or hot instruments is an essential step of the BRP technique.
View Article and Find Full Text PDFBMJ Open
December 2024
Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
Introduction: Obstructive sleep apnoea (OSA) is characterised by blood oxygen desaturations and sleep disruptions manifesting undesirable consequences. Existing treatments including oral appliances, positive airway pressure (PAP) therapy and surgically altering the anatomy of the pharynx have drawbacks including poor long-term adherence or often involving irreversible, invasive procedures. Bilateral hypoglossal nerve stimulation (HNS) is a new treatment for managing OSA, and this study is intended to determine whether an HNS system is a safe and effective treatment option for adults with OSA.
View Article and Find Full Text PDFRespir Res
January 2025
Department of Pulmonary Medicine, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
Background: Obstructive sleep apnea (OSA) is frequently associated with increased incidence and mortality of pulmonary hypertension (PH). The immune response contributes to pulmonary artery remodeling and OSA-related diseases. The immunologic factors linked to OSA-induced PH are not well understood.
View Article and Find Full Text PDFBMC Public Health
January 2025
Department of Social Medicine, School of Health Management, Harbin Medical University, Harbin, 150081, China.
Background: Accumulating research highlights that exposure to serum brominated flame retardants (BFRs) may elevate health risks. The effects of serum BFRs, both alone and in combination, on obstructive sleep apnea syndrome (OSAS) have not been thoroughly studied. Our main goal was to examine the association between individual and mixtures of serum BFRs and OSAS risk.
View Article and Find Full Text PDFClin Oral Investig
January 2025
Department of Oral and Maxillofacial Surgery, Klinikum Rechts Der Isar, School of Medicine and Health, Technische Universität München, Ismaninger Str. 22, Munich, D-81679, Germany.
Objectives: The presented study aimed to evaluate the effect of mandibular protrusion with a temporarily applied mandibular advancement device (MAD) on the posterior airway space and to determine a reliable metric constant based on a three-dimensional computed tomography (CT) evaluation.
Materials And Methods: The study population consisted of patients with oral squamous cell carcinoma who were treated at least six months prior to the follow-up CT in supine position. Each patient received an individually adjusted MAD that was temporarily applied with three different protrusion distances (P = 0 mm, P = 4 mm, and P = 8 mm) during follow-up CT.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!