Methods: 22 specimens prepared with Cention and RMGIC were embedded in primary teeth mounted in acrylic for analysing shear bond strength. Shear bond strength was analysed using a universal testing machine. The modes of failure in samples were observed under a stereomicroscope and scanning electron microscope. 22 customised samples of Cention N and RMGIC were prepared and categorised as group A and group B, respectively. The flexural and compressive strengths of these samples were evaluated using a universal testing machine.
Results: The shear bond strength of RMGIC was higher than that of Cention N, whereas the compressive and flexural strengths of Cention N were significantly higher than those of RMGIC. The modes of failure were predominantly adhesive followed by mixed failures.
Conclusion: The results of this study suggest that Cention N demonstrated superior mechanical properties compared with RMGIC and can therefore be recommended for restorations in primary posterior teeth. Cention N being a smart, esthetic, self-cured, or dual-cured material with better mechanical properties offers a wide range of applicability in primary teeth.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10776193 | PMC |
http://dx.doi.org/10.1155/2024/9420336 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!