A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dexamethasone eluting polydopaminated polycaprolactone-poly (lactic-co-glycolic) acid for treatment of tracheal stenosis. | LitMetric

Tracheal stenosis is commonly caused by injury, resulting in inflammation and fibrosis. Inhibiting inflammation and promoting epithelization can reduce recurrence after initial successful treatment of tracheal stenosis. Steroids play an important role in tracheal stenosis management. This study in vitro evaluated effectiveness of a polydopaminated polycaprolactone stent coated with dexamethasone-eluting poly(lactic-co-glycolic) acid microparticles (μPLGA) for tracheal stenosis management. Polydopamination was characterized by Raman spectroscopy and promoted epithelialization while dexamethasone delivery reduced macrophage activity, assessed by individual cell area measurements and immunofluorescent staining for inducible nitric oxide synthase (iNOS). Dexamethasone release was quantified by high-performance liquid chromatography over 30 days. Activation-related increase in cell area and iNOS production by RAW 264.7 were both reduced significantly (p < .05) through dexamethasone release. Epithelial cell spreading was higher on polydopaminated polycaprolactone (PCL) than PCL-alone (p < .05). Force required for stent migration was measured by pullout tests of PCL-μPLGA stents from cadaveric rabbit and porcine tracheas (0.425 ± 0.068 N and 1.082 ± 0.064 N, respectively) were above forces estimated to occur during forced respiration. Biomechanical support provided by stents to prevent airway collapse was assessed by comparing compressive circumferential stiffness, and stiffness of the stent was about 1/10th of the rabbit trachea (0.156 ± 0.023 N/mm vs. 1.420 ± 0.194 N/mm, respectively). A dexamethasone-loaded PCL-μPLGA stent platform can deliver dexamethasone and exhibits sufficient mechanical properties to anchor within the trachea and polydopamination of PCL is conducive to epithelial layer formation. Therefore, a polydopaminated PCL-μPLGA stent is a promising candidate for in vivo evaluation for treatment of tracheal restenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.37659DOI Listing

Publication Analysis

Top Keywords

tracheal stenosis
20
treatment tracheal
8
stenosis management
8
cell area
8
tracheal
5
stenosis
5
dexamethasone eluting
4
eluting polydopaminated
4
polydopaminated polycaprolactone-poly
4
polycaprolactone-poly lactic-co-glycolic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!