Aim: There are currently no high-quality studies comparing the static navigation technique with conventional methods of fibre post removal. The aim of this ex vivo study was to compare the effectiveness of fibre post removal between a static navigation technique and a conventional freehand technique using ultrasonics by experienced and inexperienced operators.

Methodology: Forty-eight extracted single-rooted human premolars were root-filled. A fibre post was cemented in all 48 teeth, which were then divided randomly into the following groups: static navigation group using burs; static navigation-ultrasonic group; and non-guided group using ultrasonic tips. The following parameters were evaluated for both experienced operators and inexperienced operators: reaching the gutta-percha root filling successfully, the time required to remove the entire post, the occurrence of lateral root perforations, and the amount of root dentine removed. The Kolmogorov-Smirnov test was used to examine the normality of the data; the anova test was used to compare the significant differences among groups; and Tukey tests were used for all two-by-two comparisons. The significance level was set at 0.05.

Results: In the static navigation group, the gutta-percha was reached significantly more frequently than in the non-guided group (p < .05). The static navigation approach required significantly less time than the non-guided approach to reach the gutta-percha (p < .05). The total removal of posts was significantly different between groups (p < .05), but there was no significant difference between experienced and inexperienced operators in the static navigation group (p > .05). More perforations were associated with the non-guided group than with the other two groups. The total mean loss of dentine in the non-guided group in all directions was 0.39 (±0.17) mm, with 0.25 (±0.09) mm for experienced, and 0.42 (±0.16) mm for inexperienced operators.

Conclusion: When compared to a conventional ultrasonic technique for the removal of fibre posts, the static navigation method using burs resulted in less dentine removal, more rapid access to the gutta-percha root filling, less overall time to remove the posts, and fewer complications. When using static navigation, there was no difference in performance between experienced and inexperienced operators.

Download full-text PDF

Source
http://dx.doi.org/10.1111/iej.14017DOI Listing

Publication Analysis

Top Keywords

static navigation
20
navigation technique
12
fibre post
12
comparing static
8
conventional freehand
8
freehand technique
8
ultrasonic tips
8
technique conventional
8
post removal
8
navigation group
8

Similar Publications

Magnetic Ball Chain Robots for Cardiac Arrhythmia Treatment.

IEEE Trans Med Robot Bionics

November 2024

Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.

This paper introduces a novel magnetic navigation system for cardiac ablation. The system is formed from two key elements: a magnetic ablation catheter consisting of a chain of spherical permanent magnets; and an actuation system comprised of two cart-mounted permanent magnets undergoing pure rotation. The catheter design enables a large magnetic content with the goal of minimizing the footprint of the actuation system for easier integration with the clinical workflow.

View Article and Find Full Text PDF

Dynamic Navigation in Dental Implantology.

Discoveries (Craiova)

December 2023

Periodontics Division, Department of Dentistry, All India Institute of Medical Sciences, Bathinda, Punjab, India.

Implant placement for dental rehabilitation has gained more popularity among patients in the recent past. Dental Implants are the workhorse of dentistry. Previously, the implants were placed with the help of the traditional freehand approach.

View Article and Find Full Text PDF

Design and Implementation of a CMOS-MEMS Out-of-Plane Detection Gyroscope.

Micromachines (Basel)

December 2024

Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China.

A MEMS gyroscope is a critical sensor in attitude control platforms and inertial navigation systems, which has the advantages of small size, light weight, low energy consumption, high reliability and strong anti-interference capability. This paper presents the design, simulation and fabrication of a Y-axis gyroscope with out-of-plane detection developed using CMOS-MEMS technology. The structural dimensions of the gyroscope were optimized through a multi-objective genetic algorithm, and modal, harmonic response and range simulation analyses were carried out to verify the reasonableness of the design.

View Article and Find Full Text PDF

Background: Traditional examinations of anterior cruciate ligament (ACL) injuries focus primarily on static assessments and lack the ability to evaluate dynamic knee stability. Hence, a dynamic scoring system for knee function is needed in clinical settings. This study aimed to propose a dynamic scoring system based on a large sample of normative six-degree-of-freedom (6-DOF) knee kinematics during gait, and validate its correlation with conventional outcome measurements in assessing ACL-injured knees.

View Article and Find Full Text PDF

Ambient mass spectrometry (MS) technologies have been applied to spatial metabolomic profiling of various samples in an attempt to both increase analysis speed and reduce the length of sample preparation. Recent studies, however, have focused on improving the spatial resolution of ambient approaches. Finer resolution requires greater analysis times and commensurate computing power for more sophisticated data analysis algorithms and larger data sets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!