A Method for Measuring Shaft Diameter Based on Light Stripe Image Enhancement.

Sensors (Basel)

College of Mechanical and Vehicle Engineering, Changchun University, Changchun 130022, China.

Published: January 2024

When the workpiece surface exhibits strong reflectivity, it becomes challenging to obtain accurate key measurements using non-contact, visual measurement techniques due to poor image quality. In this paper, we propose a high-precision measurement method shaft diameter based on an enhanced quality stripe image. By capturing two stripe images with different exposure times, we leverage their different characteristics. The results extracted from the low-exposure image are used to perform grayscale correction on the high-exposure image, improving the distribution of stripe grayscale and resulting in more accurate extraction results for the center points. The incorporation of different measurement positions and angles further enhanced measurement precision and robustness. Additionally, ellipse fitting is employed to derive shaft diameter. This method was applied to the profiles of different cross-sections and angles within the same shaft segment. To reduce the shape error of the shaft measurement, the average of these measurements was taken as the estimate of the average diameter for the shaft segment. In the experiments, the average shaft diameters determined by averaging elliptical estimations were compared with shaft diameters obtained using a coordinate measuring machine (CMM) the maximum error and the minimum error were respectively 18 μm and 7 μm; the average error was 11 μm; and the root mean squared error of the multiple measurement results was 10.98 μm. The measurement accuracy achieved is six times higher than that obtained from the unprocessed stripe images.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10781218PMC
http://dx.doi.org/10.3390/s24010303DOI Listing

Publication Analysis

Top Keywords

shaft diameter
12
shaft
8
diameter based
8
stripe image
8
stripe images
8
shaft segment
8
shaft diameters
8
error μm
8
measurement
7
stripe
5

Similar Publications

Background: This study examines the relationship between the anterior offset of the tibial intramedullary nail (TIN) entry point and the tibial shaft axis to enhance the fit and alignment of TINs, using transparent 3D-CT in an accurate lateral view to minimize rotational artifacts.

Methods: Data were collected from 100 adult patients undergoing tibial CT scans. Measurements included the anterior offset from the tibial axis to the entry point, tibial tubercle offset, tibial plateau length, posterior slope, tibial length, isthmus diameter, and the isthmus-to-tibial length ratio.

View Article and Find Full Text PDF

Fractures of the humerus are common on the midshaft of the bone, often causing injury to the nutrient artery. Successful fracture repair and healing requires preservation of the blood supply to the long bones which is conveyed through the nutrient foramina (NF). The topography of long bone NF varies in different populations.

View Article and Find Full Text PDF

A novel design for double-bending elliptical vibration boring device and its performance evaluation.

Ultrasonics

January 2025

State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China.

Steel precision matching parts are widely used in aerospace and automobiles. In order to ensure the stability of the system, the matching parts' mating surfaces, such as inner holes and outer shafts, are required to achieve nano-surface roughness and submicron-shape accuracy. Diamond-cutting technology is generally used for ultra-precision machining processes.

View Article and Find Full Text PDF

Background: Loss of key-pinch sensation after median nerve injury poses significant functional detriment. Nerve transfers are utilized to improve function after nerve injury and size matching of donor and recipient nerves is important to optimize success. This anthropometric study investigates the anatomy of the superficial branch of the radial nerve (SBRN) to the thumb and index finger and explores radial to median sensory nerve transfers, a necessary but not heavily discussed facet of nerve transfers for the hand.

View Article and Find Full Text PDF

Background: Afro-textured hair exhibits distinct physicochemical properties with possible variations in measurable hair parameters. Standardized documentation of trichoscopic norms of afro-textured hair in indigenous Africans is notably lacking.

Methods: A cross-sectional study involving 122 South Africans of both genders of African ancestry (mean age 20.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!