Amputees typically experience changes in residual limb volume in their daily lives. It causes an uncomfortable fit of the socket by applying high pressure on the sensitive area of the residual limb or by loosening the socket. In this study, we developed a transfemoral prosthetic socket for above-the-knee amputees that ensures a good socket fit by maintaining uniform and constant contact pressure despite volume changes in the residual limb. The socket has two air bladders in the posterior femoral region, and the pneumatic controller is located on the tibia of the prosthesis. The pneumatic system aims to minimize unstable fitting of the socket and improve walking performance by inflating or deflating the air bladder. The developed socket autonomously maintains the air pressure inside the prosthetic socket at a steady-state error of 3 mmHg or less by adjusting the amount of air in the air bladder via closed-loop control. In the clinical trial, amputee participants walked on flat and inclined surfaces. The displacement between the residual limb and socket during the gait cycle was reduced by up to 33.4% after air injection into the socket. The inflatable bladder increased the knee flexion angle on the affected side, resulting in increased stride length and gait velocity. The pneumatic socket provides a stable and comfortable walking experience not only when walking on flat ground but also on slopes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10780925 | PMC |
http://dx.doi.org/10.3390/s24010133 | DOI Listing |
Med J Islam Repub Iran
September 2024
Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran.
Background: Limb loss can negatively affect the psychological and physical well-being, mobility, and social life of people with lower limb amputation. Participating in physical activities is of great importance for these people. This study aimed to explore factors affecting the physical activity of Iraqi lower-limb amputees.
View Article and Find Full Text PDFJ Biomech
January 2025
Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, 151 boulevard de l'Hôpital, 75013 Paris, France. Electronic address:
Improper socket fitting in lower-limb prostheses can lead to significant complications, including pain, skin lesions, and pressure ulcers. Current suspension and socket design practices rely predominantly on visual inspection of the residual limb and patient feedback. Monitoring stress distribution at the residual limb/socket interface offers a more objective approach.
View Article and Find Full Text PDFJ R Soc Interface
January 2025
Department of Mechanical Engineering, Imperial College London, London, UK.
Following lower limb amputation residuum skin from the lower leg is used to reconstruct the residual limb. Unlike skin on the sole of the foot (plantar skin), leg skin is not inherently load bearing. Despite this, leg skin is required to be load bearing in the prosthetic socket.
View Article and Find Full Text PDFLife (Basel)
November 2024
Pediatric Orthopedics and Traumatology, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
Background: Fibrous dysplasia (FD) is a rare condition in which normal spongy and cortical bone is replaced by non-neoplastic fibrous tissue, leading to weakened bone matrix and increased risk of pathological fractures and deformities. Treating these deformities poses a significant challenge for surgeons. While various cases of surgical stabilization and limb lengthening using intramedullary nails have been reported, there is limited evidence on the use of Motorized Intramedullary Limb-Lengthening Nails (MILLNs) in FD patients.
View Article and Find Full Text PDFBrain Sci
December 2024
Department of Kinesiology, Indiana University, 1025 E 7th St, Bloomington, IN 47405, USA.
Background/objectives: Lower limb cutaneous reflex amplitudes can modulate across gait, which helps humans adjust rhythmic motor outputs to maintain balance in an ever-changing environment. Preliminary evidence suggests people who suffer from repetitive ankle sprains and residual feelings of giving way demonstrate altered cutaneous reflex patterns in the gastrocnemius. However, before cutaneous reflex assessment can be implemented as a clinical outcome measure, there is a need to substantiate these early findings by measuring reflex amplitudes across longer latency periods and exploring the variability of reflexes within each subject.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!