A Non-Matrix-Matched Calibration Method for In Situ Major and Trace Element Analysis of Scheelite by Nanosecond LA-ICP-MS.

Molecules

Laboratory of Mineralization and Dynamics, College of Earth Sciences and Land Resources, Chang'an University, 126 Yanta Road, Xi'an 710054, China.

Published: December 2023

In this work, a reliable and robust in situ non-matrix-matched calibration method is proposed for element composition determination in scheelite samples. With external calibration against the silicate glass standard reference material NIST SRM 610, the concentrations of both major elements (Ca and W) and trace elements (Si, Fe, Mo, Y, rare earth elements, etc.) in scheelite are determined using an ArF 193 nm excimer nanosecond laser ablation-inductively coupled plasma mass spectrometer (LA-ICP-MS). Here, the ablation was performed by hole drilling under a helium (He) environment using a laser spot size of 35 μm and a laser repetition of 5 Hz, and the aerosols were then transported to a quadrupole ICP-MS by a mixture of He and make-up gas argon (Ar) with a total gas flow rate of 1.6 L/min. Results showed that there was no apparent matrix effect between the NIST SRM 610 and scheelite by this proposed method. With internal standardization against W, the obtained concentrations of CaO and WO were found to yield an average matrix CaO/WO mass fraction ratio of 0.245 (2σ = 0.003, = 19), which agreed well with the value of 0.243 (2σ = 0.002, = 15) from electron probe microanalysis (EPMA). Furthermore, the accuracy of trace element analyses with this proposed non-matrix-matched calibration in situ method was evaluated by comparing the concentration results with those from bulk analysis by solution nebulizer ICP-MS (SN-ICP-MS). It was found that the quantification results from LA-ICP-MS and SN-ICP-MS were comparable, in particular showing a relative concentration bias of the total ∑REE+Y contents of less than 2%. This confirmed that scheelites can be accurately analyzed in situ by LA-ICP-MS without matrix-matched calibration standards. By using this developed in situ method, the element compositions in a series of scheelite samples from different W-associated deposits in China were successfully quantified, promising further genetic process investigation and associated geologic activities of the polymetallic resources.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10779717PMC
http://dx.doi.org/10.3390/molecules29010051DOI Listing

Publication Analysis

Top Keywords

non-matrix-matched calibration
12
calibration method
8
trace element
8
scheelite samples
8
nist srm
8
srm 610
8
situ method
8
method
5
situ
5
scheelite
5

Similar Publications

Preparation of REE-doped CaF single crystals for accurate determination of REE concentrations in CaF crystals via UV-LA-ICP-MS.

Talanta

April 2025

Key Laboratory of Testing and Tracing of Rare Earth Products, State Administration for Market Regulation, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China; Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China. Electronic address:

Accurate determination of rare earth element (REE) concentrations in CaF crystals using UV-LA-ICP-MS is important but challenging due to the lack of matrix-matched reference materials. In this study, a REE-doped CaF single crystal (CaF-05), prepared via the Bridgman-Stockbarger technique, was systematically characterized to assess its optical properties, homogeneity, and stability. Analyses using portable laser irradiation, UV-vis spectroscopy, back scatter electron (BSE) imaging, and cathodoluminescence (CL) demonstrated that the crystal possesses high optical quality and exhibits distinct optical adsorption properties compared to the silicate reference material NIST SRM 610.

View Article and Find Full Text PDF

Characterization of biogenic selenium nanoparticles in hypersaline media by single particle inductively coupled plasma mass spectrometry: Haloferax mediterranei case.

Anal Chim Acta

January 2025

Multidisciplinary Institute for Environmental Studies "Ramón Margalef", University of Alicante, Ap. 99, E-03080, Alicante, Spain; Biochemistry, Molecular Biology, Edaphology and Agricultural Chemistry Department, Faculty of Sciences, University of Alicante, Ap. 99, E-03080 Alicante, Spain.

Article Synopsis
  • - This study focuses on improving the methodology for using single particle inductively coupled plasma mass spectrometry (spICP-MS) to analyze biogenic selenium nanoparticles (SeNPs) created by halophilic microorganisms, particularly in hypersaline environments.
  • - The research found that, with the right conditions, spICP-MS can accurately measure SeNPs in high-salt solutions without needing correction factors, and the technique showed low detection limits for both size and concentration.
  • - The results confirmed that the microorganism Haloferax mediterranei can produce SeNPs in the presence of selenite, while selenate does not lead to particle formation, with size and concentration varying based on the experimental conditions.
View Article and Find Full Text PDF

Laser ablation inductively coupled plasma - mass spectrometry (LA-ICP-MS) is a frequently used microanalytical technique in elemental analysis of solid samples. In most instances the use of matrix-matched calibration standards is necessary for the accurate determination of elemental concentrations. However, the main drawback of this approach is the limited availability of certified reference materials.

View Article and Find Full Text PDF

A Non-Matrix-Matched Calibration Method for In Situ Major and Trace Element Analysis of Scheelite by Nanosecond LA-ICP-MS.

Molecules

December 2023

Laboratory of Mineralization and Dynamics, College of Earth Sciences and Land Resources, Chang'an University, 126 Yanta Road, Xi'an 710054, China.

In this work, a reliable and robust in situ non-matrix-matched calibration method is proposed for element composition determination in scheelite samples. With external calibration against the silicate glass standard reference material NIST SRM 610, the concentrations of both major elements (Ca and W) and trace elements (Si, Fe, Mo, Y, rare earth elements, etc.) in scheelite are determined using an ArF 193 nm excimer nanosecond laser ablation-inductively coupled plasma mass spectrometer (LA-ICP-MS).

View Article and Find Full Text PDF

Rationale: Boron isotopes are a powerful tool for pH reconstruction in marine carbonates and as a tracer for fluid-mineral interaction in geochemistry. Microanalytical approaches based on laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) often suffer from effects induced by the sample matrix. In this study, we investigate matrix-independent analyses of B isotopic ratios and apply this technique to cold-water corals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!