A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preserflo MicroShunt: Efficacy and Endothelial Cell Density. | LitMetric

Prcis: A main safety concern associated with new glaucoma implants is corneal endothelial cell loss, which could even be observed in already established procedures.

Purpose: The purpose of this study was to evaluate the efficacy and corneal safety, especially corneal endothelial cell loss (ECL), after Preserflo MicroShunt implantation.

Methods: A monocentric, prospective clinical observational study of patients with a follow-up of at least 12 months who underwent Preserflo MicroShunt implantation at the Department of Ophthalmology, University Hospital of Düsseldorf, Germany, between January 2020 and October 2021. Endothelial cell density (ECD), the distance between the tip of the implant and the corneal endothelium, and the success of the surgery were analyzed.

Results: In total, 14 eyes of 12 patients were included. After a mean follow-up of 20±2.7 months intraocular pressure was significantly reduced by 8.2 mm Hg (P=0.0041); in 28.6% of patients, a revision surgery was necessary. Reduction of preoperative and follow-up ECD was not statistically significant (ECL of 45 cells/mm2, ECDpreoperative=2074±703.6 cells/mm2, ECDlast follow-up=2029±742.3 cells/mm2, P=0.42). A longer intracameral shunt tube length correlated significantly with a higher distance between the shunt tip and corneal endothelium (r=0.61, P=0.036).

Conclusions: Preserflo MicroShunt effectively lowered intraocular pressure without substantial ECL after a minimum follow-up period of 17 months.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000002325DOI Listing

Publication Analysis

Top Keywords

preserflo microshunt
16
endothelial cell
16
cell density
8
corneal endothelial
8
cell loss
8
corneal endothelium
8
intraocular pressure
8
corneal
5
preserflo
4
microshunt efficacy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!