Hummingbirds use distinct control strategies for forward and hovering flight.

Proc Biol Sci

Department of Zoology, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z4.

Published: January 2024

The detection of optic flow is important for generating optomotor responses to mediate retinal image stabilization, and it can also be used during ongoing locomotion for centring and velocity control. Previous work in hummingbirds has separately examined the roles of optic flow during hovering and when centring through a narrow passage during forward flight. To develop a hypothesis for the visual control of forward flight velocity, we examined the behaviour of hummingbirds in a flight tunnel where optic flow could be systematically manipulated. In all treatments, the animals exhibited periods of forward flight interspersed with bouts of spontaneous hovering. Hummingbirds flew fastest when they had a reliable signal of optic flow. All optic flow manipulations caused slower flight, suggesting that hummingbirds had an expected optic flow magnitude that was disrupted. In addition, upward and downward optic flow drove optomotor responses for maintaining altitude during forward flight. When hummingbirds made voluntary transitions to hovering, optomotor responses were observed to all directions. Collectively, these results are consistent with hummingbirds controlling flight speed via mechanisms that use an internal forward model to predict expected optic flow whereas flight altitude and hovering position are controlled more directly by sensory feedback from the environment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10777153PMC
http://dx.doi.org/10.1098/rspb.2023.2155DOI Listing

Publication Analysis

Top Keywords

optic flow
32
forward flight
16
optomotor responses
12
flight
9
optic
8
flow
8
expected optic
8
hummingbirds
7
forward
6
hovering
5

Similar Publications

We describe a patient with severe Arnold Chiari Malformation and syringomyelia who underwent gynecological laparoscopy in an emergency context; no brain imaging was available. We here report the successful use of optic nerve sheath diameter (ONSD) and middle cerebral artery (MCA) velocity measurements as surrogate monitoring for cerebral blood flow and intracranial pressure, respectively. MCA velocity was low when assessed after peritoneal insufflation and ONSD increased to 6.

View Article and Find Full Text PDF

Aim: To compare the macular and optic nerve perfusion and vascular architecture using optical coherence tomography angiography (OCTA) in normal eyes of Egyptian (Caucasians) and South Asian (Asians) volunteers.

Methods: Cross-sectional analytical OCTA study performed on 90 eyes of South Asian (=45) and Egyptians (=45) were analyzed. All participants underwent best-corrected visual acuity test, slit lamp, and fundus examination.

View Article and Find Full Text PDF

Glaucoma is a chronic optic neuropathy that causes characteristic visual field defects and is considered one of the leading causes of irreversible vision loss worldwide. Lowering intraocular pressure is the only proven treatment for glaucoma. Medical therapy is usually the first-line treatment for open-angle glaucoma and ocular hypertension.

View Article and Find Full Text PDF

Oestrogen and progesterone fluctuate cyclically in women throughout their adult lives. Although these hormones cross the blood-retinal barrier and bind to intraocular receptors, their effects remain unclear. We present the first review to date on associations between posterior pole structures-specifically the macula, choroid, and optic disc-and both the menstrual cycle and post-menopausal period, utilising multimodal imaging techniques in healthy adult non-pregnant women.

View Article and Find Full Text PDF

Illusions of self-motion (vection) can be improved by adding global visual oscillation to patterns of optic flow. Here we examined whether adding apparent visual oscillation (based on four-stroke apparent motion-4SAM) also improves vection. This apparent vertical oscillation was added to self-motion displays simulating constant velocity leftward self-motion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!