Purpose: Fran is one of the most popular CrossFit benchmark workouts used to control CrossFitters' improvements. Detailed physiological characterization of Fran is needed for a more specific evaluation of CrossFitters' training performance improvements. The aim of the study was to analyze the oxygen uptake (V˙O2) kinetics and characterize the energy system contributions and the degree of postexercise fatigue of the unbroken Fran.

Methods: Twenty trained CrossFitters performed Fran at maximal exertion. V˙O2 and heart-rate kinetics were assessed at baseline and during and post-Fran. Blood lactate and glucose concentrations and muscular fatigue were measured at baseline and in the recovery period.

Results: A marked increase in V˙O2 kinetics was observed at the beginning of Fran, remaining elevated until the end (V˙O2peak: 49.2 [3.7] mL·kg-1·min-1, V˙O2 amplitude: 35.8 [5.2] mL·kg-1·min-1, time delay: 4.7 [2.5] s and time constant: 23.7 [11.1] s; mean [SD]). Aerobic, anaerobic lactic, and alactic pathways accounted for 62% (4%), 26% (4%), and 12% (2%) of energy contribution. Reduction in muscle function in jumping ability (jump height: 8% [6%], peak force: 6% [4%], and maximum velocity: 4% [2%]) and plank prone test (46% [20%]) was observed in the recovery period.

Conclusions: The Fran unbroken workout is a high-intensity effort associated with an elevated metabolic response. This pattern of energy response highlights the primary contribution of aerobic energy metabolism, even during short and very intense CrossFit workouts, and that recovery can take >24 hours due to cumulative fatigue.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijspp.2023-0201DOI Listing

Publication Analysis

Top Keywords

oxygen uptake
8
muscle function
8
trained crossfitters
8
v˙o2 kinetics
8
the fran crossfit
4
crossfit workout
4
workout oxygen
4
kinetics
4
uptake kinetics
4
kinetics energetics
4

Similar Publications

Introduction: The maximal fat oxidation (MFO) and the exercise intensity that provokes MFO (FATMAX) are inversely associated with cardiometabolic risk factors in healthy young sedentary adults. However, how both cardiorespiratory fitness (CRF) level and sex influence MFO during exercise and the FATMAX is seldom analyzed.

Objectives: This study is aimed at determining the influence of CRF and sex on MFO.

View Article and Find Full Text PDF

Background: Ulcerative colitis (UC) is a chronic and recurrent digestive tract disease that can lead to significant morbidity and mortality. The pathogenesis of UC is intricately associated with the presence of reactive oxygen species (ROS). Prussian blue (PB), an inorganic nanozyme with potent antioxidant properties, has been extensively applied in the treatment of various inflammatory conditions and tumors.

View Article and Find Full Text PDF

Synthetic Bilirubin-Based Nanomedicine Protects Against Renal Ischemia/Reperfusion Injury Through Antioxidant and Immune-Modulating Activity.

Adv Healthc Mater

January 2025

Department of Biological Sciences, KAIST Institute for the BioCentury, Center for Precision Bio-Nanomedicine, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.

Renal ischemia/reperfusion injury (IRI) is a common form of acute kidney injury. The basic mechanism underlying renal IRI is acute inflammation, where oxidative stress plays an important role. Although bilirubin exhibits potent reactive oxygen species (ROS)-scavenging properties, its clinical application is hindered by problems associated with solubility, stability, and toxicity.

View Article and Find Full Text PDF

Incidence of adverse outcome events rises as patients with advanced illness approach end-of-life. Exposures that tend to occur near end-of-life, for example, use of wheelchair, oxygen therapy and palliative care, may therefore be found associated with the incidence of the adverse outcomes. We propose a concept of reverse time-to-death (rTTD) and its use for the time-scale in time-to-event analysis based on partial likelihood to mitigate the time-varying confounding.

View Article and Find Full Text PDF

This study aims to assess the reliability and accuracy of a novel portable cardiopulmonary function meter, "Booster," developed by our research group, across various exercise intensities and modalities. The study was segmented into reliability and validity assessments. Twenty-two male participants underwent reliability testing, conducting two sequential tests on a treadmill while wearing the Booster to measure VO and VE among other parameters at increasing intensities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!